INDIVIDUAJ&TANK INFORMATION AND TOT RESULTS <br />TEST DATE: 07/07/11 8501 N MOPAC EXPRESSWAY, SUITE 400 WORK ORDER NUMBER: 2282072 <br />AUSTIN, TEXAS 78759 (512) 451-6334 <br />CLIENT: VALERO SITE: VALERO 3641 <br />Tank ID: #1 <br />Product: UNLEADED <br />Capacity in gallons: 12,041 <br />Diameter in inches: 128.00 <br />Length in inches: 218 <br />Material: DW STEEL <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />i Tank manifolded: No <br />Bottom to top fill in inches: <br />182.0 <br />Vent manifolded: YES <br />Bottom to grade in inches: <br />199.0 <br />Vapor recovery manifolded: YES <br />Fill pipe length in inches: <br />54.0 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Overspill protection: YES <br />Stage 1 vapor recovery: <br />DUAL <br />Installed: ATG <br />Stage II vapor recovery: <br />ASSIST <br />CP installed on: / / <br />Test leak rate ml/m: <br />189.0 <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />200.0 <br />50 <br />875 <br />260 <br />11:50 <br />16:10 <br />0.000 <br />PASS <br />PRESSURE <br />RED JACKET <br />NOT <br />TESTED <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Impact Valves Operational: YES <br />Printed 07/15/201109:32 MTUTTLE <br />Make: <br />RED JACKET <br />Model: <br />Fxiv <br />S/N: <br />40602-0233 <br />NOT <br />Open time in sec: <br />5.00 <br />TESTED <br />Holding psi: <br />38 <br />Resiliency cc: <br />160 <br />Test leak rate ml/m: <br />189.0 <br />Metering psi: <br />11 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />200.0 <br />50 <br />875 <br />260 <br />11:50 <br />16:10 <br />0.000 <br />PASS <br />PRESSURE <br />RED JACKET <br />NOT <br />TESTED <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Impact Valves Operational: YES <br />Printed 07/15/201109:32 MTUTTLE <br />