Laserfiche WebLink
Lyt`.'L X 1 1 V/iril i <T 0 A 0 H lJxox ` jL:jX"k 1 $1' X k t71 1 lvl i <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, 14 h and Safety Code; Chapter 16, Division 3 Title 23, fidwornia Code of Regulations <br />This form must be used to document testing and servicing nitoring equipment. If more than one monitoring system co panel is installed at the facility, a separate <br />certification or report mi,st,be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system ownwh)perator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: VALERO 3641 <br />Site Address: 1210 E. HAMMER LANE <br />WEST LANE <br />Facility Contact Person: MGR - ALISA <br />Make/Model of Monitoring System: EMC <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />City: STOCKTON CA Zip: 95210 <br />Contact Phone No: 477-3111 <br />Date of Testing/Service: 07/07/2011 <br />Work Order Number: 2282072 <br />Tank ID: 1 UNLEADED <br />Tank ID: 2 <br />X In -Tank Gauging Probe. <br />Model: MAG <br />X In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 460 <br />Annular Space or Vault Sensor. <br />Model: 460 <br />X Piping Sumpfrrench Sensor(s). <br />Model: 208 <br />Piping Sumpfrrench Sensor(s). <br />Model: 208 <br />X Fill Sump Sensor(s). <br />Model: 208 <br />Fill Sump Sensors). <br />Model: 208 <br />X Mechanical Line Leak Detector. <br />Model: FX1V <br />X Mechanical Line Leak Detector. <br />Model: FX1V <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />X Tank Overfill/High-Level Sensor. <br />Model: EXT ALARM <br />Tank Overfill/High-Level Sensor, <br />Model: EXT ALARM <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: PREMIUM <br />Tank ID: <br />71 In -Tank Gauging Probe. <br />Model: MAG <br />In -Tank Gauging Probe. <br />Model: <br />X Annular Space or Vault Sensor. <br />Model: 460 <br />Annular Space or Vault Sensor. <br />Model: <br />X Piping Sump/Trench Sensor(s). <br />Model: 208 <br />Piping Sumprrrench Sensor(s). <br />Model: <br />X Fill Sump Sensor(s). <br />Model: 208 <br />Fill Sump Sensor(s). <br />Model: <br />X Mechanical Line Leak Detector. <br />Model: FX1V <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: EXT ALARM <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: 3/4 <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />7 Dispenser Containment Sensor(s) <br />Model: <br />X� Shear Valve(s). <br />X Shear Valves) <br />X❑ Dispenser Containment Float(s) and Chain(s). <br />—X-1 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />FlDispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Fx-lShear Valve(s). <br />Shear Valve(s). <br />[XI Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />F] Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />" If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply):X❑ System set-up ff] Alarm history report <br />Technician Name (print): KRISTOPHER BELL <br />Signature: <br />Certification No.: B33709 License. No.: 743160 (Class 'A' General Enginering Contractor License) <br />Testing Company Name:Tanknology Phone No.: (800) 800-4633 <br />Site Address: 11000 N. MoPac Expressway, suite 500, Austin, TX 78759 Date of Testing/Servicing: 07/07/2011 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />