COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2024 2:54:41 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />P, Tervldic43W <br />TEST DATE: 07/09/09 8501 N MOPAC EXPRESSWAY, SUITE 400 WORK ORDER NUMBER: 2267634 <br />AUSTIN, TEXAS 78759 (512) 451-6334 <br />CLIENT: VALERO SITE: ULTRAMAR 3641 <br />Tank ID: #1 <br />Product: UNLEADED <br />Capacity in gallons: 12,041 <br />Diameter in inches: 128.00 <br />Length in inches: 218 <br />Material: DW STEEL <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />i Tank manifolded: No <br />Bottom to top fill in inches: <br />182.0 <br />Vent manifolded: YES <br />Bottom to grade in inches: <br />199.0 <br />Vapor recovery manifolded: YES <br />FIII pipe length in inches: <br />54.0 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Overspill protection: YES <br />Stage I vapor recovery: <br />DUAL <br />Installed: ATG <br />Stage II vapor recovery: <br />ASSIST <br />CP installed on: / / <br />Test leak rate ml/m: <br />189.0 <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />100.0 <br />50 <br />70 <br />30 <br />08:45 <br />09:15 <br />0.014 <br />PASS <br />PRESSURE <br />RED JACKET <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Impact Valves Operational: YES <br />Printed 08/04/2009 08:10 ACRAMER <br />Make: <br />RED JACKET <br />Model: <br />Fx1V <br />S/N: <br />0233 <br />NOT <br />Open time in sec: <br />4.00 <br />TESTED <br />Holding psi: <br />21 <br />Resiliency cc: <br />105 <br />Test leak rate ml/m: <br />189.0 <br />Metering psi: <br />13 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />100.0 <br />50 <br />70 <br />30 <br />08:45 <br />09:15 <br />0.014 <br />PASS <br />PRESSURE <br />RED JACKET <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Impact Valves Operational: YES <br />Printed 08/04/2009 08:10 ACRAMER <br />