My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2005-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2024 2:54:41 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2010
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2005-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
471
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ah <br /> MW <br /> INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> rankwiagy <br /> TEST DATE: 07/08/10 8501 N MOPAC EXPRESSWAY,SUITE 400 WORK ORDER NUMBER: 2275703 <br /> AUSTIN,TEXAS 78759(512)451-6334 <br /> CLIENT: VALERO SITE: VALERO 3641 <br /> Tank ID: #1 1 Tank manifolded: NO Bottom to top fill in inches: 182.0 <br /> Product: UNLEADED Vent manifolded: YES Bottom to grade in inches: 199.0 <br /> Capacity in gallons: 12,041 Vapor recovery manifolded: YES Fill pipe length in inches: 54.0 <br /> Diameter in inches: 128.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 218 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> 11113 <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: RED JACKET <br /> Fluid volume in gallons: Model: Fx1V <br /> Tank water level in inches: S/N: unreadable <br /> Test time: NOT Open time in sec: 4.00 <br /> Number of thermisters: TESTED Holding psi: 14 NOT <br /> Specific gravity: Resiliency cc: 120 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 12 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: BASS <br /> COMMENTS COMMENTS <br /> Test time: <br /> Ullage volume: Material: DRi FIBERG <br /> Ullage pressure: Diameter(in): 2.0 <br /> Results: Length (ft): 100.0 <br /> Test psi: 5o <br /> DATA FOR UTS-4T ONLY: Bleedback cc: 5 <br /> Time of test 1: Test time(min): 30 <br /> Temperature: NOT Start time: 12:00 NOT NOT NOT <br /> Flow rate(cfh): TESTED End time: 12:30 TESTED TESTED TESTED <br /> Time of test 2: Final gph: 0.000 <br /> Temperature: Result: PASS <br /> Flow rate(cfh): Pump type: PRESSURE <br /> Time of test 3: Pump make: RED JACKET <br /> Temperature: <br /> Flow rate(cfh): Impact Valves Operational: YES <br /> COMMENTS COMMENTS <br /> Printed 07/22/2010 08:04 ACRAMER <br />
The URL can be used to link to this page
Your browser does not support the video tag.