My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 4:18:43 PM
Creation date
6/23/2020 6:43:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
486
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> M <br /> K <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 &BEEN OND <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si4ov.org/ehd <br /> 'n <br /> Underground Storage Tank ProgramInspectiOn, Report <br /> Facility Name: Facility Phone: Date: <br /> TIWANA GAS&FOOD (209)477-3111 June 26, 2017 <br /> Facility Address: CERS ID: <br /> 1210 E HAMMER LN, STOCKTON, CA 95210 10181355 <br /> Inspection Contact: Title: Phone: <br /> Vic Sutti Manager (209)477-3111 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -LIST FACILITY <br /> Consent For: Consent Given By: <br /> N Inspection N Photos 0 Samples Vic Sutti, Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 03/01/2018 Kaylynn Rammell 06/27/2018 <br /> Service Technician Manufacturer's Training: <br /> VMI, 11/21/17;VR, 02/03/18;TT, 03/31/20 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File'Review <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees Ei V u R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system c V o R o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V Ei R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current m V m R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan c V Ei R Ei COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V ci R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed m V u R Ei COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing Ei V Ei R c COS <br /> 109 CCR 2637 Failed to test secondary containment Ei V Ei R Ei COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days ii V Ei R o COS <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually m V o R ci COS <br /> 112 HSC 25284.2 Failed to test spill containers annually D V D R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ci V D R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down o V o R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change Win 30 days Ei V Ei R Ei COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification Ei V ii R Ei COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after Ej V o R c COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R 13 COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R Ei COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification o V Ei R Ei COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report o V o R 13 COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored Ei V o R i:i COS <br /> ----777777-7- <br /> ZOn-Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o EiR E)COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years ii V Ei R o COS <br /> FA0003730 PR0231125 SCO01 06/26/2017 <br /> EHD 23-01 Rev.09/22/16 Page 1 of 5 Underground Storage Tank Program OIR <br /> 9171 9690 0935 0151 6827 56 <br />
The URL can be used to link to this page
Your browser does not support the video tag.