• • <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.slgov.org/ehd <br /> Underground Storage Tank Program hiSpection Report <br /> Facility Name: Facility Address: Date: <br /> TIWANA GAS&FOOD 1210 E HAMMER LN, STOCKTON June 26, 2017 <br /> SUO"RY OF VIOLATIONS <br /> (CLASS[,,CLASS 11,or MINOR-Noticeto Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Indicate on the map the location of all annular and sump <br /> sensors,float and chains(in the under dispenser containments), submersible turbine pumps,and line leak <br /> detectors. A site plan must be submitted identifying the locations where monitoring will be performed. Immediately <br /> log into the California Environmental Reporting System(CERS)at http://cers.calepa.ca.gov/and upload a copy of <br /> the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually. <br /> Annual monitoring system certification and leak detector testing were last performed on June 13, 2016 and was due <br /> by June 2017. Testing on the 91 line leak detector has not been completed and is over 5 months past due. These <br /> tests are required once every 12 months. Immediately schedule the 91 line leak detector test and provide 48 hours <br /> notification to the EHD. Please be aware that a follow up inspection will be charged at our current hourly rate. <br /> This is a Class II violation. <br /> 315 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 91-product sump. Ifwater could enter into the secondary containment by precipitation or <br /> infiltration, it must be removed and disposed of properly. Immediately remove this liquid, make a hazardous waste <br /> determination per Title 22 hazardous waste regulations, and manage it accordingly. Ensure that the 91-product <br /> sump is maintained free of liquid. <br /> This is a minor violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br /> The 87 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting a <br /> 3-gallon per hour leak at 10 psi. Immediately have a properly licensed,trained, and certified contractor repair or <br /> replace the failed leak detector(LG 113-x listed, if applicable)and obtain a permit within one business day from the <br /> EHD. If the failed leak detector can't be replaced immediately,there is a possibility that the 87 UST system may be <br /> red tagged to prevent fuel inputs. <br /> This is a repeat violation, Class II. <br /> 319 CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The 87-product spill container failed when tested. All USTs shall be equipped with a spill container that has a <br /> minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into the primary <br /> container or provide a means to keep the container empty. Immediately contact a properly licensed,trained, and <br /> certified contractor to repair or replace the drain in the spill container under permit and inspection of the EHD. If a <br /> spill container can't be installed immediately,there is a possibility that the 87 UST system may be red tagged to <br /> prevent fuel inputs. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> FA0003730 PR0231125 SCO01 06/26/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />