My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_1999-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:00 AM
Creation date
6/23/2020 6:44:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2003
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_1999-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� ECO/OP MULTI.!&T SPILL CONTAINMENT MWOLES <br /> Features Riser Spacing <br /> °E 3►) <br /> ®Raintight Service-Buna-N gaskets on the <br /> manhole and spill bucket mounting rings help <br /> prevent contamination of the sump area from <br /> '.°4p� �f•�o. .0 <br /> surface water intrusion. <br /> ®Highway 20 Load Rating-The rugged <br /> diamond plate steel manhole covers,as <br /> well as the cast iron (RT)or aluminum(SC) <br /> spill container covers meet H2O Load Rating <br /> requirements. <br /> ®Spill Container and Manhole Positive I.D. <br /> System-Special recesses cast into spill <br /> container covers and machined into manhole <br /> lids allow"Peel&Stick"tags to be attached <br /> to the lids. Matching bucket tags can be _ <br /> affixed to the inside of the spill container <br /> to prevent covers from getting switched. <br /> ®CARB Certified-311 Series Approval Letter <br /> #93-25,511 and 611 Series Approval Letter <br /> #92-12. <br /> ®Fill/Vapor Ports-Configurations are <br /> available to accommodate a single fill riser, <br /> dual ports for both a fill and vapor riser, and <br /> triple and quad ports for multiple fill and ♦Fastener Options-Two types of ®Custom Multi-Port Manholes- <br /> vapor risers. Vapor ports can be supplied fasteners are available to secure Contact your P0MECO/0PW <br /> with or without containment buckets. the manhole lid and monitoring port representative. <br /> •Port Configurations-Standard port to mounting rings.Standard are <br /> locations match the popular riserspacings /1s 18 hex head bolts.Optional are Powder Coated Rings&Covers- <br /> p pAvailable upon request. <br /> (12", 14", 16"or 24")and bung configurations POMECO/OPW Roto-Lock Fasteners. <br /> The POMECO/OPW Roto-Lock <br /> on underground storage tanks. Custom port system enables a secure,watertight <br /> locations are easily accommodated. connection without the need to <br /> ®Monitoring Ports-Bolt-down,gasketed locate threaded bolt holes on <br /> monitoring ports can be incorporated into the the mounting ring. <br /> manhole cover to provide observation access <br /> to the sump without removing the entire <br /> cover.Standard port diameter is 5"(13 cm) <br /> with larger ports available upon request. { <br /> ®Manhole Cover Sizes-Standard bolt-down <br /> manhole cover diameters of 30"(76 cm), ' <br /> 37"(94 cm),42"(107 cm),and 48"(122 cm) <br /> allow ample access to the sump area. _ <br /> Provision for a X'-13 lifting eyebolt is w= <br /> provided on 42"and 48"models. Heavy-duty <br /> reinforced lid options are also available. <br /> ` ®Spill Container Cover Options-Standard <br /> spill container options include the patented" <br /> POMECO/OPW dam and groove Raintight - <br /> (RT)design and the watertight Sealable <br /> Cover(SC)"plumber's plug"design. The <br /> _ Raintight cover features a finger-grip lifting <br /> facility and an integral seal.The sealable <br /> cover features a cam-operated mechanism <br /> p <br /> that expands the seal against the vertical ;•' •, ��; " a <br /> wall of the mounting ring.Both of thesex <br /> water-shedding covers are protected by h <br /> mp -jL <br /> raised mounting rings.A below-grade(BG) x .. <br /> option is available which provides watertight <br /> underground containment vessels while _ <br /> maintaining a non-watertight flush manhole <br /> r coversurface. - <br /> North America Toll Free—TELEPHONE:(800)422.2525•Fax:(800)421-3297.Email:domesticsalesna,opw-fc.com <br /> VV International—TELEPHONE:(513)870-3315 or(513)870-3261®Fax:(513)870-3157®Email:intlsales@opw-fc.com <br /> www.opw-fc.com <br /> n®via"c®w Pyr ©Copyright 2003,OPW Fueling Components®P.O.Box 405003®Cincinnati,OH 45240-5003®Printed in USA®3/03 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.