Laserfiche WebLink
Page Y of <br />7. U ER -DISPENSER CONTAINMENT ( TESTING <br />Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional Engineer ❑ <br />Other (Specify) <br />Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br />Other (Specify) <br />Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br />Under -Dispenser Containment Number Below <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Conoco Phillips -2705447 <br />1469 E HAMMER LN <br />STOCKTON, CA 95210 <br />n05071 -S13989 Testing <br />UDC Manufacturer: Pv <br />UDC Material: <br />UDC Depth: <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />u <br />k <br />u <br />Height from UDC Bottom to u <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />testing: <br />e <br />c <br />t2"'Above Highest <br />Tested' <br />2" Above Highest <br />2" Above Highest <br />2" Above Highest <br />Portion of UDC <br />etration <br />Penetration <br />Penetration <br />Penetration <br />[IYes ElNo NA® <br />Does turbine shut down whenUDC <br />[IYes ❑ No NAM <br />❑ Yes ❑ No NA® <br />[IYes ❑ No NA® <br />sensor detects liquid. <br />Turbine shutdown response time ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />Is system programmed for fail- ❑ Yes ❑ No NA® <br />safe shutdown?* <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NAIZI <br />❑ Yes ❑ No NA® <br />Was fail-safe verified to be ❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />❑ Yes ❑ No NA® <br />o erational?* <br />Wait time between applying <br />pressure/vacuum/water and 15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />starting test <br />Test Start Time: s 2 2 <br />_ 2 7 —•: y <br />> JG <br />Initial Reading (RD:y <br />, yS1 Z /. 7/ <br />J <br />Test End Time: Y."9 9 + lk <br />2--41 *rs <br />, 2 <br />Final Reading (RF): IZ,f Z 2L ME <br />. 7S 9 6 <br />-3 9'V2 <br />Test Duration: 15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />15 Min 15 Min <br />Change in Reading (RF-RO: 0 2e , 0f Cj <br />, &®C) a OpOl <br />Pass/Fail Threshold or Criteria: -0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />-0.0020 -0.0020 <br />Rif•09. <br />N1 <br />-. <br />.. <br />50 Yes ❑ No NAE] <br />ER Yes ❑ No NAE] <br />[I Yes ❑ No NAE] <br />Was sensor removed for testing? 0 Yes ❑ No NAE] <br />Was sensor properly replaced and RYes E]No NA[] <br />g1 Yes No NA <br />g) <br />® Yes E]No NAE] <br />ElYes [I No NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Conoco Phillips -2705447 <br />1469 E HAMMER LN <br />STOCKTON, CA 95210 <br />n05071 -S13989 Testing <br />