My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:03:59 PM
Creation date
6/23/2020 6:44:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2004-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />q <br />® ■/ Y <br />TEST DATE:05/05/05 8501 N MOPAC EXPRESSWAY, SUITE 400 WORK ORDER NUMBER2236036 <br />CLIENT: CONOCO- PHILLIPS AUSTIN, TEXAS 78759 (512) 451-6334 SITE:CONOCO PHILLIPS #2705447 <br />Tank ID: DSL 4 <br />Product: DIESEL <br />Capacity in gallons: i0, 369 <br />Diameter in inches: 120.00 <br />Length in inches: 214 <br />Material: DW FIBERG <br />COMMENTS <br />Start (in) <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water <br />Test time: <br />Inclinometer reading: <br />VacuTect Test Type: <br />VacuTect Probe Entry Point: <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Start time: <br />End time: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />Tank manifolded: No <br />Vent manifolded: NO <br />Vapor recovery manifolded: NO <br />Overfill protection: YES <br />Overspill protection: YES <br />Installed: ATG <br />CP installed on: / / <br />End (in) <br />Make: <br />Bubble Ullage Model: <br />S/N: <br />Open time in sec: <br />NOT Holding psi: <br />TESTED Resiliency cc: <br />Test leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />130.0 <br />NOT NOT <br />TESTED TESTED <br />PRESSURE <br />RED JACKET <br />Bottom to top fill in inches: <br />Bottom to grade in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: <br />Stage I vapor recovery: NONE <br />Stage II vapor recovery: NONE <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />FE PETRO <br />MLD <br />00010656 <br />3.00 <br />3 <br />70 NOT <br />189.0 TESTED <br />10 <br />3.00 <br />PASS <br />NOT <br />TESTED <br />Impact Valves Operational: YES <br />NOT <br />TESTED <br />Printed 05/19/2005 08:11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.