My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:24:34 PM
Creation date
6/23/2020 6:44:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street,Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 1469 E Hammer Lane, Stockton July 19, 2010 <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&Safety Code;CCR=CA Code of Regulations;V=Violation;RV=Repeat Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) LIDCs,and sumps(if necessary)not inspected;(c)(5)required test dates not checked or noted;(c)(6) X <br /> employee training not verified;(a)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(q Designated operator employee training:(1)not performed;(2)not current for at least one employee <br /> on site;(3)to not kept <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 <br /> 24 CCR 2638 days;(e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair,replacement,calibration,or certification;(f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment component that was certified,repaired,or replaced <br /> 25 HSC 25291(f) Annual line leak detector test not performed (MI) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636(D(4) Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (11112) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (11111) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (MI) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) O erational permit not amended when LIST storage and/or monitoring system changed <br /> 34 HSC 25298(b) Permit to temporarily close LIST system not obtained <br /> 35 HSC 25298(c) Permit to close LIST sntem not obtained <br /> 36 HSC 25299(%2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) Illegally abandoned LIST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> 39 CCR 2631.1(a) LIST system is not compatible with the substance stored <br /> (9(6) Emergenc ' Emergency generator systems <br /> 40 CCR 2636 <br /> y generator monitoring system not checked daily or log not kept if no leak detector (MI) <br /> 41 HSC 25281.5 b 3 Unburied fuel iin not visually inspected at least monthly or log not kept (MI) <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06/30/04) <br /> VPH STstems HSC 25290.1 (installed on or after 07/01104) <br /> Compatibility and permeability requirements:(a)LIST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631(b)and(d)for a UST systern installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> I HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> I HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the <br /> I HSC 25290.2(d) entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space <br /> I of the LIST system not maintained <br /> HSC 25290.10) LIST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2) <br /> 48 HSC 25290,2(i) inert gas pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> EHD ins pe"I" Phone: UIC <br /> (209)468-2986 Septic system: <br /> r❑1 Serves�t20 people/day <br /> oaiv y: Title: F Receives other than sanitary waste <br /> 1-f Other disposal methods: <br /> Dry wells/French Drains <br /> EHD 23-02-002 REV 06/28/10 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.