My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 1:24:34 PM
Creation date
6/23/2020 6:44:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2010
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_2008-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 6 <br /> •" UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN— PAGE 2 <br /> VI. REPORTING AND RECORD KEEPING <br /> We will report/record any overfill,spill,or unauthorized release from a UST system as indicated in this plan. <br /> Recordable Releases: Any unauthorized release from primary containment which the UST operator is able to clean up within eight(8)hours after the release was <br /> detected or should reasonably have been detected,and which does not escape from secondary containment,does not increase the hazard of fire or explosion,and does <br /> not cause any deterioration of secondary containment,must be recorded in the facility's monitoring records Monitoring records must include: <br /> The UST operator's name and telephone number; <br /> ➢ A list of the types,quantities,and concentrations of hazardous substances released; <br /> ➢ A description of the actions taken to control and clean up the release; <br /> ➢ The method and location of disposal of the released hazardous substances,and whether a hazardous waste manifest was or will be used; <br /> A description of actions taken to repair the UST and to prevent future releases; <br /> ➢ A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment <br /> Reportable Releases: Any overfill,spill,or unauthorized release which escapes from secondary containment(or primary containment if no secondary containment <br /> exists),increases the hazard of fire or explosion,or causes any deterioration of secondary containment,is a reportable release Reportable releases are also recordable. <br /> Within 24 hours after a reportable release has been detected,or should have been detected, we will notify the local agency administering the UST program of the <br /> release,investigate the release,and take immediate measures to stop the release Ifnecessary,or if required by the local agency,remaining stored product/waste will <br /> be removed from the UST to prevent further releases or facilitate corrective action If an emergency exists,we will notify the State Office of Emergency Services <br /> Within five(5)working days of a reportable release,we will submit to the local agency a full written report containing all of the following information to the extent <br /> that the information is known at the time of filing the report: <br /> The UST owner's or operator's name and telephone number; <br /> ➢ A list of the types,quantities,and concentrations of hazardous materials released; <br /> ➢ The approximate date of the release; <br /> ➢ The date on which the release was discovered; <br /> The date on which the release was stopped; <br /> ➢ A description of actions taken to control and/or stop the release; <br /> A A description of corrective and remedial actions, including investigations which were undertaken and will be conducted to determine the nature and extent of <br /> soil,ground water or surface water contamination due to the release; <br /> ➢ The method(s)of cleanup implemented to date,proposed cleanup actions,and a schedule for implementing the proposed actions; <br /> A The method(s)and location(s)of disposal of'relcased hazardous materials and any contaminated soils,groundwater,or surface water. <br /> D Copies of any hazardous waste manifests used for off-site transport of hazardous wastes associated with clean-up activity; <br /> A description of proposed methods for any repair or replacement of'UST system primary/secondary containment systems; <br /> ➢ A description of additional actions taken to prevent future releases <br /> We will follow the reporting procedures described above if any of the following conditions occur: <br /> A recordable unauthorized release can not be cleaned up or is still under investigation within eight(8)hours of detection; <br /> ➢ Released hazardous substances are discovered at the UST site or in the surrounding area; <br /> ➢ Unusual operating conditions are observed,including erratic behavior of product dispensing equipment,sudden loss of product,or the unexplained presence of <br /> water in the tank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> ➢ Monitoring results from UST system monitoring equipment/methods indicate that a release may have occurred,unless the monitoring equipment is found to be <br /> defective and is immediately repaired,recalibrated,or replaced,and additional monitoring does not confirm the initial results <br /> Record Retention: Monitoring records and written reports of unauthorized releases must be maintained on-site(or off-site at a readily available location,if approved <br /> by the local agency)for at least 3 years Hazardous waste shipping/disposal records(e g,manifests)must be maintained for at least 3 years from the date of'shipment. <br /> VII. OWNER/OPERATOR.SIGNATURE <br /> CERTIFICATIO certify that a information provided herein is true and accurate to the best of my knowledge. <br /> OWN SIGN R DATE. R70 <br /> OPE T E(print) R71 OWNER/OPERATOR TIAE R72 <br /> Chuck J. Softich Manager of Compliance & Maintenance <br /> (Agency Use Only) This plan has been reviewed and: ❑Approved ❑Approved With Conditions ❑Disapproved <br /> Local Agency Signature: Date: <br /> CIN-0228-3/3 www.unidocs.org Rev.04/02/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.