0 WO-8286 <br /> Monitoring System Certification RECEIVED <br /> D. Results of Testing/Servicing SIEP 1 12017 <br /> Sof fare Version Installed:329.01 ENVIRONMENTAL HEALTH <br /> PER <br /> Com plete the follo ing checklist: <br /> F-1 Yes ONo* Is the audible alarm operational? <br /> E)Yes [I No* Is the visual alarm operational'? <br /> 0 Yes ElNo* Were all sensors visually inspected,functionally tested,and confirmed operational'? <br /> [ Yes FlNo* Was sensor installed at lo-west point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> nyes rINo* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br /> EIN/A operational? <br /> El Yes ONo* For pressurized piping system.,;, does the turbine automatically shut down if the piping secondary containment <br /> []N/A monitoring system detects a leak, fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apphv) 0 Sump/Trench Sensors; [:]Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failureldisconnection? DYes, [:]No. <br /> Dyes ONo* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> BN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? 0/ <br /> /0 <br /> ElYes* 0No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer nairic and model for all replacement parts in Section E,below. <br /> B Yes* []No Was liquid found inside any secondary containment systems designed as dry systems? (Check a//that app/v) <br /> ElProduct, []Water, If yes,describe causes in Section E,below. <br /> E]Yes []No" Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Dyes E]No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Removed and replaced L8: Diesel Annular Sensor V/R 794390-409 <br /> Tested for alarm, shut down and Sensor out. Applied Monitor Label to Sensor cable. <br /> Removed liquid from 87, 89, 91, and diesel sumps and all spill containers and put into existing drums on-site <br /> for proper disposal. <br /> Only tested the 1,8: Diesel Annular Sensor after replacement. <br /> Page 2 of 3 <br />