My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2002-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 1:48:44 PM
Creation date
6/23/2020 6:44:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2009
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_2002-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
449
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sep 04 Q9 07:59a Reliable PetroleumA 209-845-8953 p.2 <br /> UNI RING <br /> SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited-Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form trust be used to document testing and servicing of monitoring equipment. A�eaarate certification or report must be prepared for each <br /> monitoring system controlpanel by the technician who performs the work. A copy of this form must be provided to the tank system ownerloperdtor. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility Name: PARKWOOD GAS&.FOOD )Bldg No.: <br /> Site Address: 1612 W. Hammer Lane City: Stockton Zip: 95206 <br /> Facility Contact Person: Pato Tiwana Contact Phone No.: (209) 482-2580 <br /> Make/Model of Monitoring System: Gilbarco EMC Date of Testing/Servicing: 811112009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicates ecirie a ui meat ins cted/serviced: <br /> FOAnnular <br /> : T-1 Supreme Tank ID: T-2 Unleaded <br /> nk Gauging Probe. Model: ❑In-Tank Ganging Probe. Model: <br /> Space or Vault Sensor. Model: PA02591144000 ®Annular Space or Vault Sensor. Model: PA02591144000 Sump/Trench Sensor(s), Model: PA0259 10 ®Piping Sump/Trench Senson(s), Model: PA02592000010 <br /> ❑Fill Sump Sensor(s). Model: ❑Fitt Sump Sensor(s). Model: <br /> ®Mechanical Line teak Detector. Model: 99 L02000 Z Mechanical Line Leak Detector. Model: 99�D2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Linc Leak Detector. Model.- <br /> 0 <br /> Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T-3 Diesel Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑to-Tank Gauging Probe, Model: <br /> Annular Space or Vault Sensor. Model: PA02591144000 ©Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sencor(s). Model: PA02592000010 <br /> ❑Piping Sump Trench Sensor(s). Model: <br /> ❑ <br /> Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: LD 2000 Q Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section Eon Pa e 2 . ❑Tank Overfill?High-Levet Sensor. Model: <br /> g ) [I Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 112 Dispenser ID: 314 <br /> I]Dispenser Containment Sensor(s). Model: <br /> i0 Dispenser Containment Sensw(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). 0 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 516 Dispenser ID: 718 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sertsor(s). Model: 794380-208 <br /> ®Shear Vatve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment FIoat(s)and Chain(s). <br /> Dispenser ID: Dispenser 11D: <br /> ❑Dispenser-Containment Sensor(s). Model: <br /> ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Floats)and Chain(s). ❑Dispenser Containment Float(0 and Chain(s). <br /> *if the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser aa:the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers, <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,i have also <br /> attached a copy of the report;(check all that apply): System set-up ®Alarm history report <br /> Technician Name(print): Robert Barnhart Signature: fr�2��,1I" <br /> Certification No.: B35969 License.No.: 883706 <br /> Testing Company Name: Relllable Petroleum Service Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 521 Branding.Iron Street, Oakland CA 95361 Date of Testing(Servicing: 81111 <br /> Page 1 of 4 <br /> U`-036—114 w»w.anidocs org <br /> Rev.01117lpg <br />
The URL can be used to link to this page
Your browser does not support the video tag.