My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 2:55:56 PM
Creation date
6/23/2020 6:44:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California�IVA <br />Q a <br />Authority Mted: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of egu ons <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provi`l'HEALTH <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems wi s Mdat <br />A. General information D" R'��' 'N E__NT <br />Facility Name: PARKWOOD SHELL Bldg. No.: <br />Site Address: 1612 W HAMMER LN City: STOCKTON Zip: 95209 <br />Facility Contact <br />Person: PAUL Contact Phone No.: (209) 931-3549 <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 5-9-17 <br />B. Inventory of Equipment Tested/Certified <br />Check the annronriate boxes to indicate specific eauinment inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 91 <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 2 <br />® In -Tank Gauging Probe. <br />Model: MAG 2 <br />® Annular Space or Vault Sensor. <br />Model: <br />420 <br />® Annular Space or Vault Sensor. <br />Model: 420 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIESEL <br />Tank ID: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 2 <br />❑ In -Tank Gauging Probe. <br />Model: <br />S*Annular Space or Vault Sensor. <br />Model: <br />420 SPLIT W 91 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® "Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />-it the tacmty contains more tanKs or aispensers, copy tnis Corm. mcivae mrormation for every tank ana dispenser at the taauty. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Dave Winkler <br />Signature: l(�� <br />. U <br />Certification No.: 5273934 -UT License No: 08-1740 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 4162 M STREET GALT, CA 95632 Date of Testing/Servicing: 5-9-17 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.