Laserfiche WebLink
SAN JOAQUIN COUNTY <br />EIWfRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web. www.sLcloy.orQ/ehd/unitiii.htmi <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/28/11 <br />Facility Address: 1612 Hammer Lane <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS 11, or MINOR -Notice to Com <br />Routine and Monitoring System Certification UST Inspection - AMENDED <br />2. Under dispenser containments 5/6 and 7/8 were installed on April 15, 2010 and six month testing was <br />due by October 15, 2010. This testing has not been completed and is 22 months past due. Secondary <br />containment testing is required six months after installation and every 36 months on a routine basis. <br />Immediately schedule this test and provide 48 hours notification to the Environmental Health Department <br />(EHD). <br />7. An alarm log and maintenance record for the following alarms was not found on site: L6 and L7 - <br />sensor out - 4-11-11. These records shall be kept on site for at least 3 years. Immediately locate and <br />maintain the alarm log and maintenance record on site and submit copies to the EHD by September 1, <br />2011. <br />23c. The designated operator failed to check that alarms were responded to appropriately on the 4/2011 <br />designated operator monthly inspection report. The missing alarms include: L6 and L7 - sensor out - <br />4-11-11. During the monthly inspection, the designated operator shall review the alarm history for the <br />previous month, check that each alarm was documented and responded to appropriately, and attach a <br />copy of the alarm history with documentation taken in response to any alarms to the monthly report. <br />Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />23d. The designated operator employee training for Paul Tiwana was not performed within the past 12 <br />months. The designated operator shall train facility employees for which he or she is responsible in the <br />proper operation and maintenance of the UST system once every 12 months. The training shall include, <br />but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and <br />submit a copy of the training records to the EHD by August 28, 2011. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WALL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD InspReceived <br />By: <br />� <br />TitEe: <br />/ <br />EHD 23-0 3 Rev 07/12/11 CONTINUATION FORMA <br />