My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-1995 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_1985-1995 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:36:52 PM
Creation date
6/23/2020 6:45:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-1995 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_1985-1995 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(See also computer- plot's or reduced data of leakage rate, Part III) <br />(Calculated leak raise shall. be based on data generated during the <br />second hour of testing) <br />Distance from grade level. and./or location at: which the test was <br />conducted (tank trop level, distance below grade level, distance <br />above grade, etc.) <br />10. Distance from grade level to location <br />test conducted: --52" <br />11. Fluid level where the test was conducted. In Tank <br />12. Does the tank show the presence of vapor pockets? <br />No <br />If yes, was the owner informed of steps that must. be taken to <br />release all vapor p(.)(-kets in order to comp.letc� testing? <br />Owners of storage tanks are under a legal obligation to report. <br />any leaking tanks to the agency having jurisdiction of the tank <br />test. <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, BAKERSFIELD, CA 9:3:308 (805) :322-.9827 <br />CAPACITY <br />8,000 gPRECISON <br />UNDERGROUND TANK TES tNARLSULTS <br />Patent Pending <br />TANK <br /># Diesel <br />PAGE 4 <br />STAT <br /># 120 <br />TEST PROCEDURES <br />TEST <br />DATE: 09/16/91 <br />Copyright 1985 <br />NDE TECHNOLOGY, <br />INC. PROPRIETARY <br />1. <br />(a) THE UNDERGROUND <br />STORAGE TANK SYSTEM CERTIFIED <br />TIGHT AT PRODUCT <br />HEIGHT EQUAL TO <br />THE GRADE LEVEL. Yes. <br />(b) Allowable leaf: <br />resolution of instrumentation <br />or allowable change <br />per California Administrative <br />Code 'Tittle 23 <br />Waters, Chapter 3 <br />Water Resources <br />Control Board Subchapter 16 <br />Underground Storage <br />Regulations, Part <br />2643 (b), Page 4.14; 0.05 gallons <br />per hour. <br />** <br />(c) MEASURED HOURLY <br />CHANGE: LOSS (+) OR GAIN <br />(-) GALLONS OR <br />NUMERICAL LEAK RATE <br />------------- <br />IS: +0.007 Gal/Hr. <br />This measurement <br />is within the legal limits as <br />defined in (b). <br />(See also computer plots <br />or reduced data of leakage <br />rate, Fart Il T) <br />Product. level. of the <br />storage system at: t tie time of <br />testing: <br />2. <br />Total product level. <br />86" <br />x¢ <br />3. <br />Fill pipe height <br />a. <br />from bottom of tank <br />129" <br />t <br />4. <br />Test pipe height <br />from bottom of tank <br />1313"�°"x <br />5. <br />Grade level <br />from bottom of tank <br />138" <br />; <br />6. <br />Tank top height from <br />bottom of tank <br />excluding piping, or <br />tank diameter 90" <br />7. <br />`fest Conduction "- <br />total time <br />Time leak rate calculated <br />2:01. Hours <br />8. <br />Start <br />13:38 <br />9. <br />End <br />15:39 <br />(See also computer- plot's or reduced data of leakage rate, Part III) <br />(Calculated leak raise shall. be based on data generated during the <br />second hour of testing) <br />Distance from grade level. and./or location at: which the test was <br />conducted (tank trop level, distance below grade level, distance <br />above grade, etc.) <br />10. Distance from grade level to location <br />test conducted: --52" <br />11. Fluid level where the test was conducted. In Tank <br />12. Does the tank show the presence of vapor pockets? <br />No <br />If yes, was the owner informed of steps that must. be taken to <br />release all vapor p(.)(-kets in order to comp.letc� testing? <br />Owners of storage tanks are under a legal obligation to report. <br />any leaking tanks to the agency having jurisdiction of the tank <br />test. <br />NDE TECHNOLOGY, INC. PROPRIETARY <br />WATT INC. 3131 FAIRHAVEN DRIVE, BAKERSFIELD, CA 9:3:308 (805) :322-.9827 <br />
The URL can be used to link to this page
Your browser does not support the video tag.