Laserfiche WebLink
INDIVIDUA NK/LINE/LEAK DETECTOR TESMEPORT NDE <br />NDE ENVIRONMENTAL CORPORThON <br />TEST DATE: October 23, 1996 WORK ORDER NUMBER: 966664 <br />CLIENT: WILKEY'S ENGINEERING, INC. SITE: QUIK-STOP <br />Tank ID: <br />2 <br />Bottom to top fill in inches: <br />132.0 <br />Product: <br />SUPER <br />Bottom to grade fill in inches: <br />140.0 <br />Capacity in gallons: <br />12,000 <br />Fill pipe length in inches: <br />41.0 <br />Diameter in inches: <br />91.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />431 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />DW FIBERG <br />Stage II vapor recovery: <br />BALANCE <br />Tank: <br />No <br />50 <br />Open time in sec: 3.00 <br />Manifolded Vent: <br />No <br />0.000 <br />Holding psi: 18 <br />V/R: <br />YES <br />Test type: PTK-88 <br />Resiliency cc: 315 <br />Test method: <br />vPLT <br />2.0 <br />New/passed Failed/replaced <br />Psi at tank bottom: <br />1.48 <br />50 <br />detector detector <br />Fluid level in inches: <br />57.00 <br />30 <br />Test method: FTA <br />UFT/OFT: <br />UFT <br />50 <br />Make: vAPoRLEss <br />Fluid volume in gallons: <br />7,975 <br />09:10 <br />Model: LD2000 <br />Water level in inches: <br />0.00 <br />0 <br />S/N: 4815 <br />Test time: <br />08:03-10:03 <br />50 <br />Open time in sec: 3.00 <br />Number of thermisters: <br />5 <br />0.000 <br />Holding psi: 18 <br />Specific gravity: <br />0.720 <br />Test type: PTK-88 <br />Resiliency cc: 315 <br />Water table depth in inches: <br />Test leak rate ing 189. o <br />Determined by (method): <br />No WELL <br />s: <br />Metering psi0 <br />psi: <br />Leak rate in gph: <br />-0.001 <br />Calib. leak in gph: 3.000 <br />RESULT: <br />PASS <br />RESULT: PASS <br />Test method: UTs-4T system <br />Test time: 10:19-11:13 <br />Ullage volume: 4,025 <br />Ullage pressure: 2.60 <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />10:43-10:53 <br />70.30 <br />0.200-0.200 <br />10:53-11:03 <br />70.30 <br />0.200-0.200 <br />11:03-11:13 <br />70.40 <br />0.200-0.200 <br />Material: DW FIBER® <br />Diameter (in): <br />2.0 <br />Length (ft): <br />60.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />100 <br />Test time (min): <br />30 <br />Test 1: start time: <br />09:00 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Test 2: start time: <br />09:10 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Test 3: start time: <br />09:20 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Final gph: <br />0.000 <br />RESULT: <br />PASS <br />Test type: PTK-88 <br />Pump type: PRESSURE Pump make: <br />FE PETRO <br />