My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:01:09 PM
Creation date
6/23/2020 6:45:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2013-2018 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1W'MrSan Joaquin County <br />Environmental Health Department <br />1868East Hazelton Avenue, Stockton, California 952D5'O232 <br />Telephone: (208)468-342UFax: (2O8)488-3433Web: <br />Facility Name: Facility Address: Date: <br />QUIK STOP MARKET #2120* 9321 N THORNTON RD, STOCKTON May 04, 2016 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The 87 -product submersible turbine pump (STP) sump 208 sensor was hanging approximately two feet above the <br />bottom nfthe STP sump and not located hodetect eleak adthe earliest opportunity. Monitoring equipment shall be <br />maintained to be able to detect a leak at the earliest possible opportunity. The sensor was relocated tnthe lowest <br />point ofthe sump bythe service technician. Ensure that all monitoring equipment iomaintained todetect aleak at <br />the earliest opportunity. <br />This was corrected on site. <br />This is a Class 11 violation. <br />309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visualalarm orstop the flow atthe UDC. <br />The BRAVO FLOATANDCHAIN for the 01-produotinthe 1-2 and 3-4 UDC sumps failed tostop the flow ofproduct at <br />the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or <br />stop the flow ofproduct otthe dispenser when itdetects aleak. After two attempts, theaervioeteohnicianac|eened <br />the area around the floats and on the third attempt, the float and chain at dispenser 1-2 passed, and at the fourth <br />attempt the float and chain atdispenser 3-4passed. <br />|This was corrected on site. <br />This is a minor violation. <br />318 HSC 25291 (e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul2003). <br />Liquid was observed in the 87 -product submersible turbine pump (STP) sump. |fwater could enter into the secondary <br />containment by precipitation or infiltration, it must be removed and disposed of properly. The service technician <br />removed approximately one cup ofliquid from the 87-pnoductSTP sump. Ensure that all sumps and annular spaces <br />are maintained free of liquid. <br />|This was corrected on site. <br />This is a minor violation. <br />325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons. <br />The 87-pruductspill container failed when tested. All spill containers shall have aminimum capacity offive gallons <br />and be capable of containing a spill or overfill until it is detected or cleaned up. The service technician replaced the <br />cap and the 87'pruduotspill container passed the one-hour hydrostatic test. (Both spill containers held five gallons of <br />water.) <br />|This was corrected on site. <br />This isominor violation. <br />| Overall Inspection Comments: | <br />On site on May 4, 2016 to perform an annual monitoring system certification, spill container and line leak detector <br />Page smo <br />
The URL can be used to link to this page
Your browser does not support the video tag.