My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:01:09 PM
Creation date
6/23/2020 6:45:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2013-2018 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 4 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />QUIK STOP MARKET #2120' <br />Facility Phone: <br />209 478-7149 <br />Date: <br />Mav 06 2015 <br />Facility Address: <br />9321 N THORNTON RD <br />STOCKTON CA 95209 <br />CERS ID: <br />10181013 <br />Inspection Contact: <br />Nachhatar Sidhu <br />Title: <br />Franchisee <br />Phone: <br />209 <br />478-7149 <br />Inspection Type: <br />ROUTINE INSPECTION - O eratin Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />Inspection Photos <br />Consent Given By: <br />Nachhatar Sidhu Franchisee <br />Service Technician Onsite: <br />Tomm Sei er <br />Exp. Date: <br />03/24/2017 J <br />Designated Operator: <br />Curtis Carpenter <br />Exp. Date: <br />03/16/2017 <br />Service Technician Manufacturer's Training <br />VMI Tester, 08/12/16-1Veeder-Root Level 4 01/23/16 <br />—M-R-775autornia Code of Regulations—R95 —=Health and Safety Code CFR =Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V <br />❑ R ❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V <br />❑ R ❑ COS <br />104 <br />CCR 2711 <br />UST Operating Permit Application for Facility and Tank information not submitted or current <br />❑ V <br />❑ R ❑ COS <br />105 <br />HSC 25286(c) <br />Current BOE number not submitted <br />❑ V <br />❑ R ❑ COS <br />106 <br />CCR 2632 <br />Monitoring and response plans not current or approved by the EHD <br />❑ V <br />❑ R ❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />❑ V <br />❑ R ❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V <br />❑ R ❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V <br />❑ R ❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R ❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V <br />❑ R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />❑ V <br />❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R ❑ COS <br />117 <br />HSC 25292.5 <br />Failed to conduct ELD testing on a system located within 1 000'of a public well <br />❑ V <br />❑ R ❑ COS <br />118 <br />HSC 25292.5 <br />Failed to repair and retest system due to failed ELD test <br />❑ V <br />❑ R ❑ COS <br />119 <br />CCR 2644.1(a)(5) <br />Failed to submit ELD test results within 60 days <br />❑ V <br />❑ R ❑ COS <br />120 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R ❑ COS <br />121 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V <br />❑ R ❑ COS <br />122 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V <br />❑ R ❑ COS <br />123 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />❑ V <br />❑ R ❑ COS <br />124 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V <br />❑ R ❑ COS <br />125 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V <br />❑ R ❑ COS <br />Received by� <br />(initial): <br />Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />05/06/2015 <br />Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.