My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2013-2018 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 2:01:09 PM
Creation date
6/23/2020 6:45:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2013-2018 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 4 <br />Wo San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.orcl/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />QUIK STOP MARKET #2120" <br />Facility Address: <br />19321 N THORNTON RD STOCKTON <br />Date: <br />[May06 2015 <br />UST System Observations <br />319 <br />HSC 25291(e) <br />water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) <br />■ V <br />■ R ❑ COS <br />320 <br />HSC 25290.1(c3), <br />25290.1(c3) <br />Secondary containment not constructed to prevent water intrusion <br />❑ V <br />❑ R ❑ COS <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />❑ V <br />❑ R ❑ COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />❑ V <br />❑ R ❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V <br />❑ R ❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />❑ V <br />❑ R ❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />❑ V <br />❑ R ❑ COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present, was overridden, or failed to meet overfill requirements <br />❑ V <br />❑ R ❑ COS <br />327 <br />HSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />❑ V <br />❑ R ❑ COS <br />328 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R ❑ COS <br />329 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V <br />❑ R ❑ COS <br />330 <br />HSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R ❑ COS <br />331 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R ❑ COS <br />332 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V <br />❑ R ❑ COS <br />333 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V <br />❑ R ❑ COS <br />Non-Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V <br />❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre-Jan 1984) not performed <br />❑ V <br />❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984) <br />❑ V <br />❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) <br />❑ V <br />❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V <br />❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V <br />❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />309 <br />CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />The Bravo box float and chain in the 1/2 91 and 3/4 91 UDC sumps failed to stop the flow of product at the dispenser <br />when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br />product at the dispenser when it detects a leak. The service technician adjusted the floats and verified functionality. <br />This is a repeat violation, Class ll. <br />Received by <br />(initial): WS <br />Inspector: <br />STACY RIVERA, Senior REHS <br />Phone: <br />(209) 468-3440 <br />Date: <br />05/06/2015 <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.