My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_1992-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 2:04:30 PM
Creation date
6/23/2020 6:45:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2001
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_1992-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
538
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
lty0u.c�s <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> .510.1 i I . .0 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT F-] 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON TE <br /> ONE ITEM F-] 2 INTERIM PERMIT F__j 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED <br /> I I <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOIDAYNEAR) D. TANK CAPACITY IN GALLONgL. <br /> 11.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A. F-]1 MOTOR VEHICLE FUEL 4 OIL B. C. la REGULAR UNLEADED F-]3 DIESEL 6 AVIATION GAS <br /> 12 PETROLEUM E] 80 EMPTY F'qgr 1 PRODUCT lb PREMIUM UNLEADED ❑ 4 GASAHOL E 7 METHANOL <br /> El 1C MIDGRADE UNLEADED ❑ 5 JET FUEL F-1 8 M85 <br /> 0 3 CHEMICAL PRODUCT El 95 UNKNOWN 2 WASTE ❑ 2 LEADED Ej 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.III: <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ]Na-1 DOUBLE WALL F__j 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM r_-] 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL E-1 4 SINGLE WALL IN A VAULT F-] 99 OTHER <br /> B. TANK ❑ I BARE STEEL F__] 2 STAINLESS STEEL l-3 FIBERGLASS 0 4 STEEL CLAD W1 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLEW/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL E] 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED 2 ALKYD LINING F-] 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR F-] 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES "Y NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP 0 2 COATING Ej 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION E] 91 NONE 44 ❑95 UNKNOWN E::] 99 OTHER <br /> SPILL CONTAINMENT INSTALLED(YEAR) - Fd OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) __^4 <br /> E.SPILL AND OVERFILL,etc. DROP TUBE YES NO STRIKER PLATE YES NO— DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION �&IPRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL 6-Af DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)k04 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELWICOATING A U 8 1001/6 METHANOL COMPATIBLEW/FFIP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION W MECHMCAL LINE 2 LINE TIGHTNESS or CONTINUOUS INTERSTITIAL M 4 ELECTRONIC LINE AUTOMATIC <br /> PUMP <br /> E:] 99 OTHER <br /> DETECTOR <br /> TESTING ..MOMTORING LEAK DETECTOR SHUTDOWN <br /> V.TANK LEAK DETECTION <br /> El 1 VISUAL CHECK ❑ 2 MANUAL INVENTORY ❑ 3 VADOZE ❑ <br /> 4 AUTOMATIC TANK F-15 GROUNDWATER ❑ 6 ANNUAL TANK <br /> RECONCILIATION MONITORING GAUGING MONITORING TESTING <br /> 7 CON ITTINUOUS INTERSTITIAL E] 8 SIR ❑ 9 WEEK EKLY <br /> MANUAL ❑10 MOTESTINGNTHLY TANK 0 95 UNKNOWN E:] 99 OTHER <br /> MORING GAUGING <br /> VLTANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NOE:] <br /> L ESTIMATED DATE LAST USED(MO/DAY/YR) NF-1—1 SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> _TANK OWNER'S NAME DATE <br /> (PRINTED&SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.40 KEE7 I?" <br /> �_ �?I I I <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE ER T EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLIOCO FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED.[fC MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PI IETHIS FORM WITH THE LOCAL AGENCY IMPLEMENTING TH RGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) t6 it <br />
The URL can be used to link to this page
Your browser does not support the video tag.