My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1992-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_1992-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 2:04:30 PM
Creation date
6/23/2020 6:45:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1992-2001
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_1992-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
538
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br />4M® For Use By All Jurisdictions Within the State of Calofmia <br />Authority AChapter 6.7, Health and Safety Code; Chapter 16, Division 23, California Code of Regulations <br />This Form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is insalled at the facility, a separate <br />certification or report must be prepared for each monitring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner operator. The owner operator must submit a copy of this onn tot a local agency regulating UST systems within 30 days of test date. Instructions are printed <br />on the back page. <br />A. General Information <br />Facility Name: KISHIDA TRUCKING <br />Site Address: 1725 ACKERMAN DR <br />Facilty Contact Person: MANAGER <br />Make/Model of Monitoring System: ofnniteC 80002 <br />B.Inventory of Equipment Tested/Certified <br />City: LODI <br />Contact Phone No: 368-0603 <br />Date of Testing/Service: 03/21/2001 <br />Word Order Number: 2216061 <br />Check the appropriate boxes to Indicate specific equipment inspected/serviced <br />CA Zip: 95240 <br />Tank ID: 1 1 Tank ID: 1 1 <br />In -Tank Gauging Probe. <br />Annular Space or Vault Sensor. <br />Piping Sump/Trench Sensor(s). <br />Fill Sump Sensor(s). <br />Mechanical Line Leak Detector. <br />Electronic Line Leak Detector. <br />Tank Overfill/High-Level Sensor. <br />Dispenser Containment Sensor(s) <br />Shear Valve(s). <br />Model: 80002 <br />Model: 80002 <br />Model: 80002 <br />Model: <br />Model: FX1 DV 4358 <br />Model: <br />Model: 80002 <br />Model: <br />Dispenser Containment Float(s) and Chains(s). <br />Other(specify equipment type and model in Section E on page 2). <br />In -Tank Gauging Probe. <br />Model: <br />Annular Space or Vault Sensor. <br />Model: <br />Piping Sump/Trench Sensor(s). <br />Model: 80002 <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: 4942 <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: 80002 <br />Dispenser Containment Sensor(s) <br />Model: <br />Shear Valve(s). <br />Model: <br />Dispenser Containment Float(s) and <br />Chains(s). <br />Other(specify equipment type and model in Section E on page 2). <br />In -Tank Gauging Probe. <br />Model: <br />In -Tank Gauging Probe. <br />Model: <br />Annular Space or Vault Sensor. <br />Model: <br />7Annular Space or Vault Sensor. <br />Model: <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Piping Sump/Trench Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Fill Sump Sensor(s). <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />Shear Valve(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and <br />Chains(s). <br />Dispenser Containment Float(s) and Chains(s). <br />Other(specify equipment type and model <br />in Section E on page 2). <br />Other(specify equipment type and model in Section E on page 2). <br />C. Certification <br />1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturer's guidelines. <br />Attached to this certificafion is information (e.g manufacturer's checklists) necessary to verify that this information is correct <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, i have also attached <br />a copy of the (Check all that apply): System set-up report ❑ Alarm history report <br />PRINTED NAME: MATT <br />SIGNATURE: A4 <br />COMPANY: Tanknology PHONE NO: (800) 800-4633 <br />page 1 of 3 <br />Based on CA form dated 05/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.