My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2002-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 3:24:31 PM
Creation date
6/23/2020 6:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2012
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2002-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S W RCB, January 2002 <br />C <br />E <br />8. FILL RISER CONTAINMENT SUMP TESTING <br />Page 6 of 0— <br />t-acility Is Not tguipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested 0 <br />TeaMethod Developed By: 0 Sump Manufacturer 0 Industry Standard Ej Professional Engineer <br />0 Other (Specify) Z/ <br />Test Meth Used: 0 Pressure 0 Vacuum i] Hydrostatic <br />0 Other (Specify) <br />Test Equipment Used. Equipment Resolution: <br />~ <br />Fill Sum # <br />Fill Sum # <br />Fill Sump# Fill Sum # <br />Sump Diameter: �. <br />Sump Depth: <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />, <br />, <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to <br />testing. <br />Portion of Sump Tested <br />Sump Material: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (R!): <br />Test End Time:t <br />Final Reading (RF): <br />Test Duration: <br />Chane in Reading RF -RI): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />0 Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass 0 Fait <br />❑ Pass ❑ Fail <br />Is there a sensor in the su <br />0 Yes 0 No <br />0 Yes ❑ No <br />0 Yes 0 No <br />❑ Yes 0 No <br />Does the sensor alarm gien <br />either product or w r is <br />detected? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes 0 No 0 NA <br />0 Yes No ❑ NA <br />Was sensor r oved for testing? <br />0 Yes 0 No ❑ NA <br />❑ Yes ❑ No DNA <br />0 Yes ❑ No ❑ NA <br />❑Yes ❑ No NA <br />Was sensq properly replaced and <br />verified functional after testing? <br />0 Yes ❑ No 0 NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />0 Yes 0 No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.