COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 4:20:10 PM
Creation date
6/23/2020 6:45:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r 1 0 0 <br />MONITORING SYSTEM CERTIFICATIONRECEIVED <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, Cali%rnia Code o/Regulations <br />NOV 2 5 2013 <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoriny <br />system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator <br />must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. ENVIRONMENTALWALTH <br />A. General Information PERMMSEFMCES <br />Facility Name: GEORGE KISHIDA TRUCKING County: SAN JOAQUIN <br />Site Address: 1725 ACKERMAN DR City: LODI <br />Facility Contact Person: KELLI Contact Phone 209-368-0603 <br />Make/Model of Monitoring System: OMNTEC Date of Testing/Servicing: 11/7/2013 <br />B. Inventory of EaUiDment Tested/Certified <br />Tank ID: T5 - DSL <br />Tank ID: T6 - DSL <br />® In -Tank Gauging Probe. <br />Model: <br />® In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: OPTIC <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: FLOAT SWITCH <br />® Piping Sump / Trench Sensor(s). <br />Model: FLOAT SWITCH <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: FXIDV <br />® Mechanical Line Leak Detector. <br />Mudd: FXIDV <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Tank ID: <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump/ Trench Sensor(s). <br />Model <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Dispenser ID: I <br />Dispenser ID: I SAT <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 2 <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />❑ Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). — <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />_ <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />•— app,up..aac uua eu 11u1caie spccuic equipment mspeeteatservtcea: <br />C. Certification I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that <br />this information is correct and a Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, I have also attached a copy of the report; (clteck all that apply): El System set-up ® Alarm history report <br />Technician Name (print): RHOME DESBIENS Signature: <br />Certification 112111RD License No.: 433159 <br />Testing Company Name: B. Z. Service Station Maintenance Phone No.: (916) 371-2380 <br />Site 1041 Triangle Court West Sacramento, CA 95605 Date of Testing/Servicing: 11/7/2013 <br />Monitoring Certification Test Report <br />1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.