Laserfiche WebLink
f <br /> Ah Ad <br /> UNIFIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- % I of 2) <br /> TYPE OF ACTION ❑1.NEW PLAN [64.CHANGE OF INFORMATION 490.1 <br /> PLAN TYPE .MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM <br /> L FACIYM iTIQN <br /> FACILITY ID#(Agency use only) 1 <br /> BUSINESS NAME(Same as FACILITY NAME) g 9A-it-4 C- 3. <br /> BUSINESS SITE ADDRESS �� 103. CITY 1/UD L Cl-l- 104. <br /> II,EQUONW11 ff, Tjti00i 0 AND PREVENTI MA LT. <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR§2632,2634,2638,2641 <br /> MONITORING EQUIPMENT IS SERVICED M-L ANNUALLY ❑ 99.OTHER S 490-3a <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN.Ek2 SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634 <br /> _ IV TANK MONITORING IS PEttT•`ORMED LISvG FQT ;QWIl�IG METHODS) <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL.)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: CYA.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490.6 <br /> PANEL MANUFACTURER: ' ✓ 490�MODEL#: flO ago s <br /> LEAK SENSOR MANUFACTURER: O /1!/ 49". 1 MODEL#(S): W(% 490.10 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TAMS).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 490.11 MODEL#: 490.13 <br /> IN-TANK PROBE MANUFACTURER: 490"14' MODEL#(S): 490.15 <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY <br /> ❑ c.WEEKLY 490.16 <br /> ❑ d.MONTHLY ❑ e.OTHERS ify): 490-1 <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. [3c.OTHER(Specify): 490-18 <br /> 49419 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCA§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MPG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 4990-21 { <br /> 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490.23 <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 490.24 <br /> 490-25 <br /> ❑ <br /> 99.OTHER (Specify): 490.26 <br /> 490-27 <br /> V.PIPE MONITORIlIG IS pERI'ORMED tJSIN THE FOIT.OWING METHOD'()(Check all that apply) <br /> CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 428 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: DRY ❑b.LIQUIDFILLED [1c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> PANEL MANUFACTURER: 6rA N-Cf'iG. 49430 MODEL#: 0IP,�tQ 490-31 <br /> 490-32 ;; <br /> LEAK SENSOR MANUFACTURER MODEL#(S): V f'Ji <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ELa.YES ❑b.NO j 4 <br /> FAILUREMISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. YES b.N d 11'4 <br /> MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g p h.LEAK TESTS AND RESTRICTS OR STOUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED L23 CCR§WQ 490.36 <br /> MLLD MANUFACTURER(S): 490-37 MODEL#(S): lV 490.39 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> ELLD MANUFACTURER(S) 490'40 MODEL#(S): 490-41 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 490-43 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49044 <br /> 4.PIPE INTEGRITY TES)PING 490.4s <br /> TEST FREQUENCY 19 a.ANNUALLY b.EVERY 3 YEARS Q c.OTHERS i 490-46490-47 <br /> Lj 5.VISUAL PIPE MONITORING. 490-49 <br /> FREQUENCY ❑ a.DALLY ❑ b.WEEKLY ❑C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 4984 <br /> Allowed for w"dtori of atburied mwmcy gatwom awl i' oW HSC25281.5 3 " <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(%x3)1• -- n ' <br /> El 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNE T 1 tYS1 EM <br /> 490.51 _--. <br /> ❑ 99.OTHER(Specify) 490.52 <br /> 90-53 <br /> NOVa 9 <br /> UPCF UST-D(12/2007)1/419`/6�, s �1p(���a AL <br />