My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_1986-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:12:40 PM
Creation date
6/23/2020 6:46:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2003
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_1986-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
475
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN WATER RESOURCES CONTRqSOARD <br /> FORM `B': UNDERGROUND STORAGE TANK PR RAM a o <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> 1O <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT5 CHANGE OF INFORMATION ❑ 7 PERMANEt T�Yj CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT r-14 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> pq <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ' ftxFARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: "J <br /> C. YEAR INSTALLED D. TANK CAPACITY IN ONS: Q AW <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF � / <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# /v C.A.S.#:N <br /> IA I <br /> III. TANK CONSTRU TION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF 1 DOUBLE WALLED F--] 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASSE�J<STEEL CLADW/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ <br /> C.INTERIOR 3 E 1 RUBBER LINED ❑ 2 ALKYD LINING PDXY LINING F-] 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED [:] 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ES ❑ NO [:]99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2 TAR OR ASPHALT ❑3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF AB VE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A 08 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST YGED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAST NK FILLED WITH <br /> SUB,STS, REMAINING IN GALLONS !/�J♦NEW�TERIAL? ❑YES ❑ NO <br /> n/ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> EE <br /> o 1 D <br /> CURRENTAGEN�FAFF�Y ID# A��D BY NAISE PHONE#WITH AREA CODE <br /> PERMIT NUMBEPERMIT APPROVAL DATE PERIYIIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANI dY A FACILITY/SITE APPLICATION, FORM `A',UNLESS RENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.