COMPLIANCE INFO_2010-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:52:45 PM
Creation date
6/23/2020 6:46:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> indicated. If the heart has stopped,trained personnel should begin cardiopulmonary resuscitation immediately. <br /> Move to fresh air. <br /> Other Promptly remove wet contaminated non-impervious clothing. Wash before re-use. Silica is listed under IARC Class <br /> Group 1,as a Carcinogen.Titanium Dioxides classified as a Group 2B carcinogen by IARC.Xylene may cause <br /> hearing impairment.Xylene also causes severe eye irritation and corrosion. <br /> SECTION V: FIRE-FIGHTING MEASURES <br /> Flash Point 150°F(66°C) <br /> Suitable extinguishing media: Alcohol-resistant foam. <br /> Carbon dioxide(CO2). <br /> Dry chemical. <br /> Dry sand. <br /> Limestone powder. <br /> Specific hazards: May generate ammonia gas. May generate toxic nitrogen oxide gases. Do not allow run- <br /> off from fire fighting to enter drains or water courses. Incomplete combustion may form <br /> carbon monoxide. Downwind personnel must be evacuated. Burning produces obnoxious <br /> and toxic fumes. <br /> Special protective equipment for Avoid contact with skin. A face shield should be worn. Use personal protective equipment. <br /> fire-fighters: Wear self contained breathing apparatus for fire fighting if necessary. <br /> Further information: Do not allow run-off from fire fighting to enter drains or water courses. <br /> SECTION VI: ACCIDENTAL RELEASE MEASURES <br /> Steps to be taken in case material is released or spilled: <br /> Personal precautions: Use self-contained breathing apparatus and chemically protective clothing. Wear suitable <br /> protective clothing,gloves and eye/face protection. Evacuate personnel to safe areas. <br /> Environmental precautions: Construct a dike to prevent spreading. <br /> Methods for cleaning up: Approach suspected leak areas with caution. Place in appropriate chemical waste container. <br /> Waste disposal methods: Disperse in accordance with federal,state and local regulations. <br /> Additional advice: If possible,stop flow of product. <br /> SECTION VII: HANDLING AND STORAGE <br /> Handling <br /> Keep away from heat,sparks,flames and all sources of ignition. WARNING!Harmful if swallowed,inhaled or absorbed through <br /> the skin. Avoid breathing vapors,mist or spray. Use adequate ventilation;wash thoroughly after handling. <br /> Storage <br /> Keep containers tightly closed in a cool and well-ventilated place below 100°F. <br /> SECTION VIII: EXPOSURE CONTROLS/PERSONAL PROTECTION <br /> Precautions to Be Taken In Use <br /> Use only with adequate ventilation. <br /> Do not get in eyes,or on skin or clothing. Do not breathe vapor or spray mist. <br /> Wash hands after using. <br /> This coating may contain materials classified as nuisance particulates(listed"as Dust'in section 2)which may be present <br /> at hazardous levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section 2,the <br /> applicable limits for nuisance dusts are ACGIH TLV 10 mg/m3(total dust),3 mg/m3(respirable fraction),OSHA PEL 15 <br /> mg/m3(total dust),5 mg/m3(respirable fraction). <br /> Ventilation: Local exhaust preferable. General exhaust acceptable if the exposure to materials in Section 2 <br /> is maintained below applicable exposure limits. Refer to OSHA Standards 1910.94,1910.107, <br /> 1910.108. <br /> Respiratory Protection: if personal exposure cannot be controlled below applicable limits by ventilation,wear a properly <br /> fitted organic vapor/particulate respirator approved by NIOSH/MSHA for protection against <br /> Page 3 of 6 <br /> Enviroline 125 Hardener 03/01/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.