My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:52:45 PM
Creation date
6/23/2020 6:46:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.skgov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Inspection date: <br />Van de Pol/ Pacific Pride <br />Jun 25, 2010 <br />Facility address: <br />UST # I <br />13 <br />14 - " <br />15 - <br />351 Beckman Rd. Lodi, CA 95241 <br />Product <br />91 <br />/DSL <br />' X 87 <br />/ <br />Facility contact: Title: Phone: <br />16 <br />17 <br />Ted Shackelford Site Manager (209) 649-8308 <br />- ADSL <br />' ADSL <br />Monitoring panel: <br />Piping system: <br />Overfill prevention: <br />violations: <br />Veeder-Root TLS -350 <br />Pressurized Suction Gravity <br />® ❑ ❑ <br />Mechanical <br />® AudibleMsual <br />M7-RDetect ❑ M&Both <br />M2-RPrev <br />Inspection type: <br />Designated operator. ICC exp. date: <br />Q Routine ® Monitoring certification ❑ InstaNation ❑ Other <br />Felix R a m i re z 6-21-10 <br />On site Service Technician's name: ICC exp. date: <br />Manutacturees training: <br />Felix Ramirez 12-13-10 <br />VR 6-25-10 VMI 11-12-11 <br /># <br />Code Section <br />VIOLATIONS <br />V <br />R <br />HSC=CA Health & Safety Code; CCR=CA Code of Regulations; V=Violation; RV=Repeat Violation <br />V <br />1 <br />HSC 25284 <br />No permit to operate <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test <br />2 <br />CCR 2637 <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test <br />3 <br />CCR 2711(b) & (c) <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />X <br />5 <br />CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />6 <br />CCR 2712(1) <br />Monitoring and/or response plan is not onsite <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/ (Mt) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of <br />7 <br />CCR 2712(b) <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />X <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre -Janus 1, 1984) not performed LMS) <br />9 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills <br />X <br />10 <br />CCR 2632(c)(2) <br />Monitorings stem is not present in the interstitials ace of a double walled UST/piping (M1) <br />11 <br />CCR 2630(d) <br />UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(Mi) <br />12 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br />X <br />containment <br />13 <br />CCR 2636(f)(1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (Mt) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631(a) <br />Primary containment is not product tight <br />15 <br />HSC 25291(a)(2) <br />Secondary containment for UST system is not tight <br />16 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />17 <br />CCR 2636 (0(2) <br />Line leak detector(s) not installed or failed to detect a3 -gallon per hour leak at 10 psi (Mt) <br />18 <br />CCR 2635(b)(1) <br />Spill container not installed, failed to contain a minimum capacity of five gallons, or failed to (M2) <br />provide a means to keep the spill container empty <br />19 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (M2) <br />21 <br />HSC 25291(e) <br />Water in 21 containment not removed, analyzed & properly disposed of <br />X <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (Mi) <br />22 <br />CCR 2650 <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />23b <br />CCR 2715(b) <br />Designated operator did not osseW a current IqKW Sy m Operator certification <br />EHD inspe <br />ak(- <br />Received by: <br />I -I 'i�k_ <br />Title: <br />� 4 <br />EHD 23-02-002 REV 04/08/10 Page 1 v T OFFICIAL INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.