ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Feb 22 1-0 04t20p EliteV Contactors 1209461342 <br />4.0 Description of the Testing Location <br />p.7 <br />Vaporless LD -2000 Addendum <br />The Vaporless system was evaluated at the Fuels Management Research Center which is located <br />in Grain Valley, Missouri and operated by Ken Wilcox Associates, Inc. All line tests were <br />conducted using regular unleaded gasoline. Testing for this addendum was conducted on a 200 <br />ft. fiberglass pipeline with a volume of 85 gallons and a 215 ft. flexible pipeline with a total <br />volume of 19.7 gallons. The bulk modulus was 34,443 psi for the rigid line and 4,485 psi for the <br />flexible pipeline. <br />The 99 LD -2000 was installed by the manufacturer in its usual configuration in a standard Red <br />Jacket pump. The Red Jacket pump was installed in a 600 gallon tank where product was <br />thermally conditioned according to the EPA protocol requirements. Product was heated or cooled <br />in the 600 gallon tank by circulating glycol and product through an external heat exchanger. Soil <br />temperatures were monitored by temperature sensors located at 2 inches, 4 inches and 12 inches <br />from the line as specified by the protocol. A single temperature sensor was located 4 inches from <br />the bottom of the product conditioning tank. The weighted soil temperature and the product tank <br />temperature at the beginning of the test were used to compute the temperature differential <br />between the soil and the product. <br />Page 5 <br />