B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br />The Interstitial Sensor for steel tanks detects the presence of liquid between the double walls of the tank. An open <br />sensor triggers a Sensor Out alarm. <br />Table 11. Interstitial Sensor for Steel Tanks Features and Console Compatibility <br />Item <br />Description <br />Form number <br />794380-420 (16 foot [4.9m] cable); 794380.460 (30 foot [9.1m] cable) <br />Operating principle <br />Float switch <br />Product activation height' <br />1.59 inches (4.05 cm) <br />Operating temperature <br />-4 to +140'F (-20 to +60T) <br />Dimensions <br />2.5" (6.4cm) high, 1.5" (3.8cm) diameter <br />Compatible consoles <br />TLS-450/TLS-450PLUS, TLS4/8601 Series, TLS -350 Series, TLS -300 Series <br />Console Interface <br />Module <br />TLS -300 Series - No input module required <br />TLS -350 Series, Interstitial/Liquid Sensor Interface Module, 8 sensor input, P/N 329358-001 <br />TLS-450/TLS-450 PLUS - Universal Sensor Module (USM), 16 sensor Input, P/N 332812-001 <br />TLS4/8601 Series - Universal Sensor Input Output Module (USIOM) (AC ver.), 12 sensor input, P/N 333238-001; (AC ver.), <br />6 sensor input, P/N 333238-002; (DC ver.), 12 sensor input, P/N 333238-003; (DC ver.), 6 sensor input, P/N 333238-004 <br />Maximum number of <br />sensors monitored per <br />console <br />TLS•300 Series (8) <br />TLS -350 Series (48) <br />TLS-4501TLS-450PLUS (32) <br />TL54/8601 Series (12) <br />Compatible fuels <br />See "Sensor Application Matrix" on page 1. <br />1For additional third party evaluation data see: http://nwglde.org/evals/veeder_root_m.html <br />Miscellaneous <br />• Riser cap and adapter kit (2") - Weatherproof <br />D - u junction box <br />P/N 312020-928 P q <br />• Installation example (see Fig. 7) Seal -off <br />Manhole <br />Rigid conduit <br />(to Console) <br />1/2" NPT <br />cord grips <br />-. <br />Appropriate reducer �" r----- ----- E:_ -- <br />with 1/2" NPT ; <br />opening for cable <br />cord grip ; <br />, <br />Leader cable <br />, I <br />Riser <br />I ' <br />, I <br />I � <br />Tank 1 <br />1 � <br />e ' <br />6 1 <br />1 <br />e 1 <br />i 1 <br />Sensor must rest t <br />on bottom of R <br />interstitial riser <br />iEA <br />
The URL can be used to link to this page
Your browser does not support the video tag.