Laserfiche WebLink
2016-08-03 11:22 V De PoL <br />1 v 2094683433 P 7/7 <br />kl'0'1*11 12a I I <br />San Joaquin County =4AV <br />Environmental Health Department pUG 2016 <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax; (209) 468-3433 Web: MM,§1gSLvzft*0� - <br />'d e <br />Or roif-F n! ri �A@Aj <br />'5 <br />Facility Name- <br />Facility Addross: <br />DOW: <br />VAN DE PCL ENT INOPACIFIg PRIDE <br />351 N BECKMAN RD-LODI <br />June L4, 2016 <br />4 UMMARViD V, 41 <br />IN <br />Item # <br />Remarks <br />207r-- <br />CCR 2716 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator documented all the alarms from the attached alarm history on the 4-26-16 and 12-4-16 <br />designated operator monthly inspection reports but failed to check that they were responded to appropriately. The <br />alarm responses are locking for the following: 3-31-16 Li Red Diesel Fill fuel alarm and 11-24-16 L2 91 Fill alarm, <br />During the monthly inspection, the designated operator shall review the alarm history for the previous month, check <br />that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />This is a repeat violation, Class 11, <br />318 <br />CCR 2636(f)(2) Leek detector failed to detect a 3.0 gph leak at 10 psi, <br />The 87 VM1 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of detecting <br />a 3 -gallon per hour leak at 10 psi, The service technician adjusted the leak detector, retested it, and it passed. <br />This is a repeat violation, Class 11. <br />2010 <br />CCR 2712(i) Prior to the routine inspection, Marty Thorpe called to inform the SJCEHD that concrete had been broken <br />and replaced over the 91 UST and that a permit had not been obtained for this work. A copy of the permit and all <br />conditions and attachments, including monitoring plans, shall be retained at the facility. Construction, repair and/or <br />removal permits are required from the EHO prior to any change, repair, or removal of UST system equipment. A failure <br />to obtain permit penalty (double permit fee) applies. Correct immediately by including the failure to obtain permit <br />penalty fee with your permit application. <br />This is a minor violation. <br />Overall Inspection Comments: <br />An inspection checklist was provided to the facility operator on the day of inspection. The EHD has written the <br />complete report which replaces the initial checklist <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, within 30 days of receiving the complete inspection repot <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br />FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Rocalvod by: Dato: <br />I . nspector: <br />inspector Phone! <br />fw6 0?4bw Printed Name and Titio: <br />ARIS VELOSO, Senior REHS <br />(209) 468-$453 <br />Pago 4 of 4 <br />