My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015-07-27 13:59 FUEL �&IVERY 12092347295 >>ma <br />San Joaquin county <br />Environmental Health Department JUL 2 7 20;� <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Tolophono. (209) 468-3420 Fax: (209) 468-3433 Wob:mKMjgov,org [MIRONMEN <br />Underground Storage Tank Program Inspection Report <br />Facility Narno: <br />Facility Address., <br />Dato; <br />VAN DE POL ENT INUPACIFIC PRIDE <br />351 N BrXKMAKIRD, LODI <br />June 25 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS 11, or MINOR- Notice to Comply} <br />Item # <br />Romarks <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan was not current when field verified for accuracy during the monitoring system certification testing. <br />The monitoring plan needs the following corrections: TA0131016(diesel) needs to list the mechanical line leak detector <br />manufacturer as Fe Petro and the model needs to be listed as STP MLD. <br />The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br />into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a repeat violation, Class 11. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted, The UST site plan diesel tank leak detector listed should <br />not be Red Jacket, It should be FE Petro STP MLD. The red diesel tank leak detector listed should not be VMI. It <br />should be FE Petro STP MLD D. <br />A site plan must be submitted identifying the locations where monitoring will be performed, Immediately log into the <br />California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST <br />Monitoring Site Plan. <br />This is a repeat violation, Class H. <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the 10.16-14 designated <br />operator monthly inspection report and failed to check that they were responded to appropriately. The missing alarms <br />include: L7 91 stp sump 9-25-14 fuel alarm. During the monthly inspection, the designated operator shall review the <br />alarm history for the previous month, check that each alarm was documented and responded to appropriately, and <br />attach a copy of the alarm history with documentation taken in response to any alarms to the monthly report. Ensure <br />that designated operators performing monthly inspections at this facility are including all of the required information on <br />the reports. <br />This is a repeat violation, Class 11, <br />314 <br />CCR 2631(a) Primary containment not tight (pro -Jul 2003). <br />Approximately a cup of diesel fuel was on each side of the diesel A B stp sump saddle, indicating a leak in the <br />primary piping system. All primary containment for the UST system must be tight. Immediately have a properly <br />licensed, trained, and certified contractor repair or replace the failed component under permit and inspection of the <br />EHD. <br />This is a repeat violation, Class 11, <br />Overall Inspection Comments: <br />On site to witness the annual monitoring system certification testing and conduct the routine inspection. <br />R®Caivo� by- <br />Inspector; phOno: Data. <br />-T% <br />(InItl <br />ARTS VEL050, Senior REHS W53 06/25/2015 <br />Pago 4 of 6 <br />9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.