Laserfiche WebLink
0 <br />D. Results of Testing/Servicing <br />Software' Version Installed: 123.02 <br />r-1.4. 4hn Wl—inh ehnrkk4f•w <br />RECEIVELO <br />i, ' N` �' ff. � <br />® Yes ' <br />❑ No* ' <br />;, Is the audible alarm operational? W, C a g TIJ r-MCDO OT4417NIT <br />® Yes ` <br />❑ No* <br />is the visual alarm operational? <br />® Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />® Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br />operation? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? <br />® N/A <br />® Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br />❑ N/A <br />fails to operate, or is electrically disconnected? if yes: which sensors initiate positive shut -down? (Check all that apply) ® Sumplrrench <br />Sensors; ® Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is <br />® N/A <br />installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating property? If so, at what percent of tank capacity <br />does the alarm trigger? % <br />❑ Yes <br />® No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name <br />and model for all replacement parts in Section E, below. <br />®Yes* <br />❑ No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />® Product; ❑ Water. If yes, describe causes in Section E, below. <br />® Yes <br />❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />® Yes <br />❑ No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />* in Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: SMALL AMOUNT OF DIESEL IN TANK 5 SUMP, CLEANED BY SITE MAINTENANCE. <br />Monitoring System Certification Page 2 of 4 2/21/07 <br />