My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 2014 Walton Engineering, Inc. __1 ' - .... "°'" 11 <br />SYffEM <br />SET-UP REPORT <br />(Page 3) <br />L12:PREMIUM <br />ANN <br />OUTPUT RELAY SETUP <br />TRI-STATE <br />(SINGLE FLOAT) <br />- - - - - - - - - - _ <br />_ IN-TANK ALARMS <br />CATEGORY <br />: ANNULAR SPACE <br />T 5:LOW PRODUCT ALARM <br />R 1:UNLEADEIi <br />TYPE: <br />LIQUID SENSOR ALMS <br />STANDARD <br />L10:FUEL ALARM <br />L14:D1ESEL ANN <br />NORMALLY CLOSED <br />L17:FUEL ALARM <br />TRI-STATE <br />(SINGLE FLOAT) <br />L18:FUEL ALARM <br />CATEGORY <br />: ANNULAR SPACE <br />L21:FUEL ALARM <br />IN-TANK ALARMS <br />L10:SENSOR OUT ALARM <br />T 3:LOW PRODUCT ALARM <br />L17:SENSOR OUT ALARM <br />L18:SENSOR OUT ALARM <br />L15:DIESEL <br />A-B ANN <br />LIQUID SENSOR ALMS <br />L21:SENSOR OUT ALARM <br />TRI-STATE <br />(SINGLE FLOAT) <br />L 8:FUEL ALARM <br />CATEGORY <br />: ANNULAR SPACE <br />L17:FUEL ALARM <br />R 6:DIESEL B <br />L18:FUEL ALARM <br />TYPE: <br />L 8:SENSOR OUT ALARM <br />STANDARD <br />L17:SENSOR OUT ALARM <br />NORMALLY CLOSED <br />L16:VENT <br />BOX <br />L18:SENSOR OUT ALARM <br />TRI-STATE <br />(SINGLE FLOAT) <br />CATEGORY <br />: OTHER SENSORS <br />R 2:PREMIUM <br />IN-TANK ALARMS <br />TYPE: <br />T 5:LOW PRODUCT ALARM <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L17:DISP <br />1-2 <br />L10:FUEL ALARM <br />TRI-STATE <br />(SINGLE FLOAT) <br />L21:FUEL ALARM <br />CATEGORY <br />: DISPENSER PAN <br />IN-TANK ALARMS <br />L10:SENSOR OUT ALARM <br />T 2:LOW PRODUCT ALARM <br />L21:SENSOR OUT ALARM <br />LIQUID SENSOR ALMS <br />L18:DISP <br />TRI-STATE <br />3-4 <br />(SINGLE FLOAT) <br />L 7:FUEL ALARM <br />L17:FUEL ALARM <br />RECONCILIATION SETUP <br />- - - _ <br />CATEGORY <br />: DISPENSER PAN <br />L18:FUEL ALARM <br />_ _ _ <br />L 7:SENSOR OUT ALARM <br />L17:SENSOR OUT ALARM <br />AUTOMATIC DAILY CLOSING <br />L19:DISP <br />5-6 <br />LIB:SENSOR OUT ALARM <br />TIME: 2:00 AM <br />TRI-STATE <br />CATEGORY <br />(SINGLE FLOAT) <br />: DISPENSER PAN <br />R 3:RED DIESEL <br />TYPE: <br />PERIODIC RECONCILIATION <br />STANDARD <br />MODE: MONTHLY <br />NORMALLY CLOSED <br />TEMP COMPENSATION <br />L20:DISP 7-8 <br />STANDARD <br />TRI-STATE <br />CATEGORY <br />(SINGLE FLOAT) <br />: DISPENSER PAN <br />IN-TANK ALARMS <br />T I:LOW PRODUCT ALARM <br />BUS SLOT FUEL METER TANK <br />- - - - - - - - - - - - <br />LIQUID SENSOR ALMS <br />TANK MAP EMPTY <br />L 6:FUEL ALARM <br />L21:DISP 9-10 <br />L19:FUEL ALARM <br />TRI-STATE <br />(SINGLE FLOAT) <br />L 6:SENSOR OUT ALARM <br />CATEGORY <br />: DISPENSER PAN <br />L19:SENSOR OUT ALARM <br />-- <br />R 4:DIESEL <br />2 WIRE CL <br />SENSOR SETUP <br />TYPE: <br />-- - - - <br />- - - - - -- <br />STANDARD <br />NORMALLY CLOSED <br />C 1:87 ANNULAR <br />ULTRA 2 <br />CATEGORY <br />ANNULAR SPACE <br />IN-TANK ALARMS <br />SOFTWARE REVISION LEVEL <br />VERSION 123.02 <br />T 4:LOW PRODUCT ALARM <br />SOFTWARE# 346123-100-C <br />LIQUID SENSOR ALMS <br />CREATED - 02.11.25.15.17 <br />L 9:FUEL ALARM <br />L20:FUEL ALARM <br />NO SOFTWARE MODULE <br />L 9:SENSOR OUT ALARM <br />SYSTEM FEATURES: <br />PERIODIC IN-TANK TESTS <br />L20:SENSOR OUT ALARM <br />ANNUAL IN-TANK TESTS <br />R 5:DIESEL A <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />RECEIVED <br />AUG 0 5 2014 <br />ENVIRONMENTAL HEALTH <br />0 2014 Walton Engineering, Inc. __1 ' - .... "°'" 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.