Laserfiche WebLink
' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />RECEIVED <br />SEP 0p§g9014of <br />SWRCB, January 2002 <br />ENVIRONMENTAL T <br />7. TANK ANNULAR <br />TESTING <br />Test Method Developed By: <br />X Tank Manufacturer ❑ Industry Standard ❑ Profe <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />X Vacuum <br />❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Gast Vacuum Pump/Vacuum Gauges in Hg. <br />Equipment Resolution: -'/2" x - 30 Hg. <br />NINE= <br />Tank # 1 <br />Tank # 2 <br />Tank # 3 <br />Tank # 4 <br />Is Tank Exempt From Testing?' <br />No <br />No <br />No <br />No <br />Tank Capacity: <br />8k <br />8k <br />l0k <br />l0k <br />Jacketed Double <br />Jacketed Double <br />Jacketed Double <br />Jacketed Double <br />Tank Material: <br />Wall Steel <br />Wall Steel <br />Wall Steel <br />Wall Steel <br />Tank Manufacturer: <br />K&T Steel <br />K&T Steel <br />K&T Steel <br />K&T Steel <br />Product Stored: <br />Dyed Diesel <br />Premium 91 <br />Regular 87 <br />Diesel-T-4 <br />Wait time between applying <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />vacuum and starting test: <br />Test Start Time: <br />10:45 <br />10:35 <br />10:25 <br />11:15 <br />Initial Reading (Ri): <br />-5 Hg. <br />-5 Hg. <br />-5 Hg. <br />-5 Hg. <br />Test End Time: <br />11:45 <br />11:35 <br />11:25 <br />12:15 <br />Final Reading (RF): <br />-5 Hg. <br />-5 Hg. <br />-5 Hg. <br />-5 Hg. <br />Test Duration: <br />I Hour <br />1 Hour <br />1 Hour <br />1 Hour <br />Change in Reading (RF-Ri): <br />0 Hg. <br />0 Hg. <br />0 Hg. <br />0 Hg. <br />Pass/Fail Threshold or Criteria: <br />No Loss in Hg. <br />No Loss in Hg. <br />No Loss in Hg. <br />No Loss in Hg- <br />g.Test <br />Tis tResult: <br />„.,,. <br />Pass <br />Psis <br />Pass <br />Pass <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced and <br />Yes <br />Yes <br />Yes <br />Yes <br />verified functional after testin ? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />