My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.7 <br />Ll <br />SWRCB, January 2002 Page of <br />17. FILL RISER CONTAINMENT SUMP TESTING <br />Facilitv is Not Eauioned With Fill Riser Containment Sumns ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Snecifv) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Em <br />Fill Sump#5-Diesel- Fill Sump # <br />A -B <br />Sump Diameter: 42" <br />Equipment Resolution: .002 <br />Fill Sump # Fill Sump # <br />Sump Depth: 44" <br />Height from Tank Top to Top of No Piping <br />Highest Piping Penetration: Penetrations <br />Height from Tank Top to Lowest 14" <br />Electrical Penetration: <br />Condition of sump prior to Dry <br />testing: <br />Portion of Sump Tested Water Line 16" <br />Sump Material: Fiberglass <br />Wait time between applying 5 Minutes <br />water and starting test: <br />Test Start Time: 1:55 <br />Initial Reading (RI): .001 <br />Test End Time: 2:25 <br />Final Reading (RF): .001 <br />Test Duration: 30 Minutes <br />Change in Reading (RF—RI): 0 <br />Pass/Fail Threshold or Criteria: .005/30 Minutes <br />Tes exult: <br />Is there a sensor in the sump? Yes <br />Does the sensor alarm when <br />either product or water is Yes <br />detected? <br />Was sensor removed for testing? Yes <br />Was sensor properly replaced and Yes <br />verified functional after testin . <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.