Laserfiche WebLink
INDIVIDUALANK/LINE/LEAK DETECTOR TEWEPORT <br />D ENVIRONMENTAL iOR <br />TEST DATE: May 23, 1996 <br />CLIENT ULTpjUQR INC <br />WORK ORDER NUMBER: 966121 <br />SITE: ULTRAMM 502 <br />Tank ID: <br />1 <br />Bottom to top fill in inches: <br />153.0 <br />Product: <br />REG UNLEAD <br />Bottom to grade fill in inches: <br />160.0 <br />Capacity in gallons: <br />12,000 <br />Fill pipe length in inches: <br />58.0 <br />Diameter in inches: <br />95.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />396 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />DSP STEEL <br />Stage II vapor recovery: <br />ASSIST <br />Tank: <br />No <br />5o <br />vol change cc: <br />Manifolded Vent: <br />YES <br />0.008 <br />RESULT: <br />WR: <br />No <br />Test type: PTK-88 <br />Pump type: PREssvRE Pump make: <br />Test method: <br />Psi at tank bottom: <br />Fluid level in inches: <br />UFT/OFT- <br />Fluid <br />FT/OFTFluid volume in gallons: <br />Water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />RESULT: <br />New/passed Failed/replaced <br />detector <br />detector <br />Test method: PTA <br />Length (ft): <br />Make: RED JACKET <br />Model: Px2 <br />50 <br />S/N: 0126950839 <br />65 <br />Open time in sec: <br />4.00 <br />Holding psi: <br />12 <br />Resiliency cc: <br />200 <br />t leak rate ml/min: <br />189.0 <br />Metering psi: <br />10 <br />Calib. leak in gph: <br />3.00 <br />RESULT: <br />PASS <br />Test method: <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />RESULT: <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />Material: Dw P=BERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />80.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />65 <br />Test time (min): <br />30 <br />Test 1: start time: <br />09:55 <br />finish psi: <br />47 <br />vol change cc: <br />15 <br />Test 2: start time: <br />10:05 <br />finish psi: <br />5o <br />vol change cc: <br />0 <br />Test 3: start time: <br />10:15 <br />finish psi: <br />5o <br />vol change cc: <br />0 <br />Final gph: <br />0.008 <br />RESULT: <br />PASS <br />Test type: PTK-88 <br />Pump type: PREssvRE Pump make: <br />RED JACKET <br />