My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1994-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_1994-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 12:01:45 PM
Creation date
6/23/2020 6:46:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2001
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_1994-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• � �ypURCp4 <br />STATE OF CALIFORNIA p ca <br />p <br />STATE WATER RESOURCES CONTROL BOARD w, <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />\ Cit IFOn N`� <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br />MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED SITZ <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED rERMIT ❑ 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />I_ TANK DESCRIPTION COMPLETE ALL ITEMS -- SPECIFY IF UNKNOWN I <br />A. OWNER'S TANK 1. D. * O <br />B. <br />B. MANUFACTURED BY: �oA)--c444 <br />C. DATE INSTALLED (MO/DAY/YEAR) <br />IN 1 PRODUCT <br />D. TANK CAPACITY IN GALLONS: /4/ pco <br />II TANK rONTFNTS IC AA IR MARKED C(1MPI FTP ITEM C_ <br />�(—� 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />A _❑ <br />B. <br />C. 1- REGUD LAR <br />❑ 3 DIESEL ❑ 6 AVIATION GAS <br />❑ 4 GASAHOL <br />2 PETROLEUM O 80 EMPTY <br />IN 1 PRODUCT <br />❑ ib PREMIUM ❑ 7 METHANOL <br />UNLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III TANK rOKIRTM ICTION MARK ONF ITEM ONI YIN ROXFS A R AND C. AND ALL THAT APPLIES IN ROX D AND F <br />A. TYPE OF1 <br />DOUBLE WALL <br />�2 <br />F--]3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />1 SINGLE WALL <br />F--]1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />F—]3 FIBERGLASS <br />4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br />8 100°/ METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING9 <br />EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />IS LINING MATERIAL COMPATIBLE WITH 100'/ METHANOL? <br />YES NO Gr, <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP5:j- <br />� l 4 FIBERGLASS REINFORCED PLASTIC <br />D. CORROSION <br />``❑ <br />PROTECTION <br />PROTECTION <br />E:]5 CATHODIC PROTECTION <br />❑ 91 NONE <br />ID 95 UNKNOWN <br />99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A <br />PRESSURE A U <br />3 GRAVITY A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A <br />DOUBLE WALL A U <br />3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br />C. MATERIAL AND <br />CORROSION <br />PROTECTION <br />A U <br />A U <br />A U <br />1 BARE STEEL <br />5 ALUMINUM <br />9 GALVANIZED STEEL <br />A U <br />A U <br />A U <br />2 STAINLESS STEEL A U <br />6 CONCRETE A U <br />10 CATHODIC PROTECTION <br />3 POLYVINYL CHLORIDE (PVC) A® FIBERGLASS PIPE <br />7 STEEL W/ COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br />A U 95 UNKNOWN A U 99 OTHER <br />D. LEAK DETECTION <br />❑ 1 <br />AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 IMNOTE STITIA ❑ 99 OTHER <br />V. TANK LEAK DETECTION <br />❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br />❑ 6 TANK TESTING �< 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATE AT LAST E,: O/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br />/�/1 SUBSTANCE REMAINING GALLONS INERT MATERIAL ? YES NO <br />THIS FORM WS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />SPRINTED 8 SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# <br />'ERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FILE THIS FORM WRHLOCAL AGENCY IMPLEMENTING THE UNDERGROUNDS i <br />NDERGROUNDST E TANK REGUL7---- <br />FORM B (12-91)-� <br />00346-R6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.