My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1994-2001
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_1994-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 12:01:45 PM
Creation date
6/23/2020 6:46:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2001
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_1994-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEST DATE: 04/12/01 <br />CLIENT:ULTRAMAR INC <br />Tank ID: <br />12K <br />Product: <br />REGULAR <br />Capacity in gallons: <br />12,094 <br />Diameter in inches: <br />95.00 <br />Length in inches: <br />399 <br />Material: <br />DW STEEL <br />COMMENTS <br />TANK INFORMATION ANI <br />.® <br />TankmWbgy <br />8900 SHOAL CREEK, BUILDING 200 <br />AUSTIN, TEXAS 78757 (512) 451-6334 <br />1 Tank manifolded: No <br />Vent manifolded: yES <br />Vapor recovery manifolded: yES <br />Overfill protection: yEs <br />Overspill protection: yEs <br />Installed: ATG <br />CP installed on: / / <br />Dipped Water Level: <br />Dipped Product Level: <br />Probe Water Level: <br />Ingress Detected: Water Bubble <br />Test time: <br />Inclinometer reading: <br />VacuTect Test Type: NOT <br />VacuTect Probe Entry Point: TESTED <br />Pressure Set Point: <br />Tank water level in inches: <br />Water table depth in inches: <br />Determined by (method): <br />Result: <br />COMMENTS <br />COMMENTS <br />Make: <br />Ullage Model: <br />S/N: <br />Open time in sec: <br />Holding psi: <br />Resiliency cc: <br />Test leak rate ml/m: <br />Metering psi: <br />Calib. leak in gph: <br />Results: <br />Material: DW FIBERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />80.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />0 <br />Test time (min): <br />30 <br />Start time: <br />08:40 <br />End time: <br />09:10 <br />Final gph: <br />-0.006 <br />Result: <br />PASS <br />Pump type: <br />PRESSURE <br />Pump make: <br />RED JACKET <br />COMMENTS <br />NOT <br />TESTED <br />WORK ORDER NUMBER2216330 <br />SITE:U,TRAMAR #502 <br />Bottom to top fill in inches: <br />153.0 <br />Bottom to grade in inches: <br />160.0 <br />Fill pipe length in inches: <br />58.0 <br />Fill pipe diameter in inches: <br />4.0 <br />Stage I vapor recovery: <br />DUAL <br />Stage II vapor recovery: <br />ASSIST <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />VAPORLESS <br />LD2000 <br />58406 <br />7.00 <br />30 <br />189.0 <br />11 <br />3.00 <br />PASS <br />• <br />4 4 • <br />Impact Valves Operational: yES <br />NOT <br />TESTED <br />Printed 04/13/2001 15:14 <br />