Laserfiche WebLink
e <br />TEST DATE: 05/06/97 <br />CLIENT: ULTRAMAR INC <br />WORK ORDER NUMBER: 2201285 <br />SITE: ULTRAMAR 502 <br />Tank ID: <br />1 <br />Fluid level in inches: <br />Bottom to top fill in inches: <br />153.0 <br />Product: <br />REG UNLEAD <br />Material: DW STEEL <br />Bottom to grade fill in inches: <br />160.0 <br />Capacity in gallons: <br />12,094 <br />Tank: No <br />Fill pipe length in inches: <br />58.0 <br />Diameter in inches: <br />95.00 <br />Manifolded Vent: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />396 <br />V/R: No <br />Stage I vapor recovery: <br />DUAL <br />10 <br />Impact Valves Operational: <br />Stage II vapor recovery: <br />ASSIST <br />COMMENTS <br />Results: <br />PASS <br />COMMENTS Result: <br />COMMENTS <br />PSI at tank bottom: <br />Newipassed L.D. <br />Fluid level in inches: <br />make: <br />VApORLESS <br />UFT/OFT: <br />Model: <br />LD2000 <br />Fluid volume in gallons: <br />S/N: <br />58405 <br />Tank water level in inches: <br />Open time in sec: <br />4.00 <br />Test time: <br />Holding psi: <br />12 <br />Number of thermisters <br />Resiliancy cc: <br />140 <br />Specific gravity: <br />Test leak rate ml/min: <br />189.0 <br />Water table depth in inches: <br />Metering psi: <br />10 <br />Determined by (method): <br />Calib. leak in gph: <br />3.00 <br />Leak rate in gph: <br />Results: <br />PASS <br />COMMENTS Result: <br />COMMENTS <br />50 <br />Test time: <br />Matenal: DW FIBERG <br />Ullage volume: <br />Diameter (in): <br />2.0 <br />Ullage pressure: <br />Length (ft): <br />80.0 <br />Results: <br />Test psi: <br />50 <br />Bleedback cc: <br />45 <br />DATA FOR UTS-4T ONLY: <br />Test time (min): <br />30 <br />Time of test 1: <br />Test 1: Start time: <br />13:40 <br />Temperature: <br />Finish psi: <br />49 <br />Flow rate (cfh): <br />Vol change cc: <br />Test 2: Start time: <br />7 <br />13:50 <br />Time of test 2: <br />Finish psi: <br />50 <br />Temperature: <br />Vol change cc: <br />Test 3: Start time: <br />0 <br />14:00 <br />Flow rate (cfh): <br />Finish psi: <br />50 <br />Time of test 3: <br />Vol change cc: <br />0 <br />Temperature: <br />Final gph: <br />0.004 <br />Flow rate (cfh): <br />COMMENTS <br />Result: PASS <br />Pump type: PRESSURE <br />Pump make: RED JACKET <br />COMMENTS <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 <br />