Laserfiche WebLink
WORT ORDER #74714 <br />11-2a-lf <br />CUSTOMER JOB LOCATION DATE: ----------- <br />CUSTOMER COMPANY CHEAPER CONTACT: JOHN JOHNSON <br />P.O. BOX 886 15 WEST GRANTLINE <br />BENICIA, CA. 94510 TRACY, CA. 95376 37 <br />707-745-6691 209-833-9619 <br />--------------------------------------------------------------------------------------------- <br />MECHANICAL LEAK. DETECTOR TEST FORM <br />------------------------------------ ---- ---------------------------------------------- <br />REG/UNL , SUPREME/UNL ®, PREMIUM/UNL j 2_=_, DIE!;EL (CIRCLE ONE & IDENTIFY OCTANE) <br />----------------- <br />SUBMERGED PUMP MFG.:—all <br />-�--- <br />LEAK DETECTOR MFG.: _Q / '$ MODEL. u / / G ° 0 1:2 SERIAL # <br />TYPE: DIAPHRAM PISTON OTHERS (Tamper Proof Seal? ® yes __X no <br />--------------------------------------------------------------------------------------------- <br />LEAK DETECTOR OPENING TIME TEST <br />1. Turn on Pump and record the step -through time from 0 psi to full pressure. `� sec <br />( Approximately 3 Seconds ) <br />----------------------------------------------------------------------------------------------- <br />FUNCTIONAL ELEMENT OPERATION TEST <br />2. Pump Running Pressure 5t` psi Shut-off Pressure /` psi <br />( 25 to 35 psi normal ) ( 8 to 20 psi normal ) <br />--------------------------------------------------------------------------------------------- <br />RESILIENCY TEST ( BLEEDBACK ) <br />4. Drain and measure amount of roduct from shut-off pressure to 0 psi too ml <br />( 50 - 110 ml for diaphragm �ype and 350 - 410 mi for Piston type ) <br />10 psi CALIBRATION <br />S. Using the calibration valve, create the proper leak rate @ 10 psi. <br />Confirm test leak @ / 9 7- ml per minute. <br />-------------------------------------SIMULATED LEAK TEST <br />6. With the simulated leak in the line active, dispense product from the nozzle. <br />Confirm flow rate through the nozzle @-----�_ 9 ®-------gallons per minute. <br />----------------------------------------- ------------------ <br />BOTTOM LINE <br />7. There are two tests the leaf; detector must pass in order for it to be considered <br />acceptable. <br />LEAS=: DETECTOR OPENING TIME TEST ( 1 l LEAK SIMULATED TEST ( 6 } <br />Diaphragm type (between 2 and 3 seconds) Flow rate through nozzle <br />Piston type (between 2 and 3.5 seconds) (between 1.5 and 3 gallons per Minute) <br />PASS FAIL L PASS FAIL <br />LEAS. DETECTOR <br />MUST PASb 301H I = IN 47 <br />PASS FAIL <br />PERFORMED BY TECHNICIAN: L►�� ��+�►�� �! l x 69 � <br />;ns- HCONNIEGDRI V..'""SACRAMENTO- CA.r- 9815 <br />916-922-2716 <br />ar\..cu \ftb \ld jw\v <br />