Laserfiche WebLink
MONITYkING SYSTEM CERTINCATION <br /> CERTIFICATION /TEST DATE: December 16, 2008 <br /> urs..,.. .m" .:# '..., ;,S`Fs.arz,ir1. fxaz'.v.;Kre,.e;.�,5.'aYm:.}.w Cit14'"7 .'Y:': `*-'sL�M.',riufl✓M:+..r).., ;':"para?. ,. Twsu .59Y'v«:,=;Xk'...,✓`157:..,s;,,.w�sa .t�,, f,h.,,,rs4:?:ANSC.,*S',,.,rx?�`. . ^s. .07,+..,r5., <br /> A1. FACILITY A2. OWNER <br /> Name Bonfare Market#35 Name Bonfare Markets, Inc. r <br /> Address 15 W.Grant Line Road,Tracy,CA 95376 Address 461 S.Milpitas Blvd.,Suite 1,Milpitas,CA 95035 <br /> Phone# 209-833-9619 Phone# 408-933-4422 <br /> Contact Danny Arca ena Contact Sean Kapoor <br /> a <br /> F. IN-TANK GAUGING/SIR EQUIPMENT: ■ Check this box if tank gauging is used only for inventory control. <br /> ❑ Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be completed if in-tank gaugung equipment is used to perform leak detection monitoring. <br /> Complete the following checklist: <br /> d..A <br /> ❑ Yes ❑ No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> ❑ Yes ❑ No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> .' ❑ Yes ❑ No* Was accuracy of system product level readings tested? <br /> El Yes ElNo* Was accuracy of system water level readings tested? <br /> El ❑ No* Were all probes reinstalled properly? <br /> ❑ Yes ❑ <br /> No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> In Section H below,describe how and when these � y <br /> * e deficiencies were or will be corrected. <br /> �C 4,..A,,u'..dd."•m�kt�a.,u,.n!>v�-r..t.,A„,�3.,A:.`� .,: ,YrtS.r ems'"t.k' 't`s.a4,�''�-sem„. 1 k.FY�t 2Y ,''�..�Yz-3S`�.� '�u^,._,' !u,Jwaw,h$na,.,a ,�sa...:.,.. .d<.E.:r.,r„ .�L t .�;; .,r�aS.Jr.?lmbw.,.us w ;-rf.nrk,�'ssan�l;tix"�,4+�� <br /> G. LINE LEAK DETECTORS (LLD): ❑ Check this box if LLDs are not installed. <br /> ,r <br /> Complete the following checklist: <br /> Yes ❑ No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance? <br /> f ❑ N/A (check all that apply) Simulated leak rate: 0 3 g.p.h.; ❑ 0.1 g.p.h.; ❑ 0.2 g.p.h. <br /> A '15 ■ Yes ❑ No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> ■ Yes ❑ No* Was the testing apparatus properly calibrated? <br /> ❑ Yes ❑ No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? ' k <br /> ■ N/A <br /> ■ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? r- <br /> ❑ N/A <br /> r , <br /> s` ■ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system is disabled <br /> ❑ N/A or disconnected? <br /> aw '` <br /> ■ Yes ❑ No* For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions it <br /> s ❑ N/A or falls a test? al <br /> � t <br /> � a <br /> ■ Yes ❑ No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> .E ❑ N/A <br /> ■ Yes ❑ No* Were all Mems on the equipment manufacturer's maintenance checklist completed � <br /> [.4. c'nC w.?{.e�,.ws:i:.., 4. .,+-,;�n<.."_,_€,..:: ,,i. .Xb:.,�,a�T..3,?lydzdt�:k,Rw'!..+&,A'Cii+,f.lvl,r'<i W4`�ld.mY f'.A 9,k•vkrG`c5r2iy:Y+:d.R w.YYx v..�'.{:o.v. «.nw'�„ �5_=.3r .Y»x,<h;a V,s,.,.,.fi.,":r-,,. �k, ,'u".,u tw'� <br /> r� <br /> In Section H below,describe how and when these deficiencies were or will be corrected. <br /> �+�Fs^-,x Yai§'1.�v;e'ah"#'dw�4s.:.,.,«,,t+ti q ir`",:,fi;'v3F na,�vf+vn+;�.+x:V:rt�a,�,3...?a%.a? �`,.€_!��-s.*.?.3u"`.`�.M, r>✓�,w3z<:+nS. -_r 7'.'nE"��'�Yss'a�"�'? �,�;t,4h.,tgRfJ�'Riv's.w,.".;':..�+�s.+#�,<t,.ri'X:,S ao'�.,..+5w�,"•^,.�:.s^3.sx��. _�. ..cr`.,:r..4z.3 t4,e's. .t;.�.f as..,a,u~v y�.T..F,W,m4,"v`,4�YlPts':' S�„�; <br /> H. COMMENTS <br /> X, <br /> e' <br /> �rns�3sr �",stir?:nti,�.��'�.���4a,rx.,,:d<,rl.�`�. �;,a �s�i;• ;�i�€��r,;w���;��,.��.r. �r�??Yf1�:e,uau#�.�"^„"f �'",•r�s��SS.r�u'��.+,tir�;#�Y:`�'�l�c,aws..,'�-�r.�.,�,,.�,,.;:".,z..,.ra�+:.xe'',�Ym...�+r�4 s.�- �rs�;�*,��.ups`:���.�m@:�:�,ma��.a,w"4�,E#r�:a•'� 4'�` `�' C�':��4�,r��' <br /> ©2006 Walton Engineering,Inc. <br /> Page 3 of 3 <br />