My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2005-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 1:58:57 PM
Creation date
6/23/2020 6:47:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2009
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\STIPULATION FOR FINAL JUDGMENT 12-2-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
409
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ANNUAL WILL CONTAINER TEV REPORT <br /> TEST DATE: December 16, 2009 <br /> A1. FACILITY A2. OWNER <br /> Name Bonfare Market#35 Name Bonfare Markets, Inc. <br /> Address 15 W.Grant Line Road,Tracy,CA 95376 Address 461 S. Milpitas Blvd.,Suite 1, Milpitas,CA 95035 <br /> Phone# 209-833-9619 Phone# 408-933-4422 <br /> Contact Danny Arcayena Contact Sean Kapoor <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E. Main Street,Stockton,CA 95202 Address P.O. Box 1025,W.Sacramento,CA 95691 <br /> Notified December 10,2009 Lic# 617238 A, B,Haz <br /> Inspector Michell Henry Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> K. SPILL CONTAINER TEST RESULTS <br /> Measuring Equipment Used: Caldwell System 2001 /Walton Engineering (Level Change Indicator) <br /> Tank Number 1 2 3 <br /> Product contained Gasoline-91 Gasoline-87 1 Gasoline-87 2 <br /> Spill container capacity (US gallons) 5 5 5 <br /> Spill container manufacturer OPW OPW OPW <br /> Spill container depth (inches) 14.00 12.50 14.50 <br /> Is the spill container located in a sump? Yes Yes Yes <br /> Does sump have a liquid sensor installed? Yes Yes Yes <br /> Condition of spill container prior to testing Wet Wet Wet <br /> Portion of spill container tested Entire Entire Entire <br /> Depth of water level from bottom (inches) 12.50 11.00 13.00 <br /> Wait time for water level to stabilize (hr:min) 0:10 0:10 0:10 <br /> Test start time 10:34 10:40 11:14 <br /> Test end time 11:04 11:10 11:44 <br /> Test duration (hr:min) 0:30 0:30 0:30 <br /> Change in water level (t 0.000 inches) 0.000 0,000 0.000 <br /> Pass/Fail threshold (0.005 inches/'/:Hr.) 0.005 0.005 0.005 <br /> TEST RESULT PASS PASS PASS <br /> L. COMMENTS: <br /> Replaced the fill cap on the 87 2 tank. <br /> WALTON <br /> Signature: ENGINEERING,INC. <br /> Technician: Bruce N.Stewart/A31131 5249892-UT Date: December 16, 2009 <br /> ©2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.