COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• i <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Haze{ton Avenue, Stockton, Cafifomia 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.orcl/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Bonfare Market #35 Facility 15 East Grant Line Road, Trac Inspection Dec 5, 2012 <br />Name: Address: y Date: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal R ulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine & Annual Monitoring System Certification <br />301 & 305. The 87 electronic relay failed to provide positive shut down during the sensor out & failed <br />safe/ power out testing and when testing the L5 Unleaded 1 sump and L6 Unleaded 2 STP sump <br />sensors. Liquid detection sensors, when dipped into liquid for testing, were able to activate an audible <br />and visual alarm but the turbines continued to run. Possible electronic issues for the 81 electronic relay. <br />All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br />product at the dispenser when it detects a leak. Correct immediately by having a properly licensed, <br />trained, and certified contractor replace the failed component with a functional component (LG 113-x <br />listed, if applicable) and obtain a permit immediately from the EHD. If the failed component can't be <br />replaced immediately, there is a possibility that the 87 UST system may be red tagged to prevent fuel <br />inputs & outputs. <br />- Corrected on site. Outside service contractor called in for repairs. Contractor MB technician Byron <br />Melendez ICC 5261224UT exp 04/13 VR A27736 exp 02/14. replaced electronic relay & verified pos` ve <br />shutdown to 87 turbine during sensor functionality test <br />311. The 87 line leak detector failed to detect a leak when tested. Per testing technician, the 87 aur• ine <br />is in constant pressure mode and turbine always on since the Veeder-Root monitoring panel can no <br />longer operate the turbine. All line leak detectors shall be capable of detecting a 3 -gallon per hour leak <br />at 10 psi. If the failed leak detector can't be replaced immediately, there is a possibility that thr- 87 UST <br />system may be red tagged to prevent fuel inputs & output. <br />- Since the 87 relay has been repaired, have a testing technician verified functionality of 87 line leak <br />detector. Submit a 48 hour advance notification to EHD to witness testing. Inspection will be billed at <br />current hourly rate. <br />Submit to SJC EHD within 30 days (1/7/13): <br />1. provide 48 hours advance notification of 87 line leak detector functionality testing to EHD <br />2. one copy of the completed "California Environmental Reporting System Lead User Authorization <br />Form" to allow EHD authorization to facility's CERS data. Businesses must submit electronic data of <br />HMBP on a state website starting 2013. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />R„ed gy Title: e <br />EHD 23-02 Rev 04/1 /12 Page 3 UST INSPECTION REPOF <br />
The URL can be used to link to this page
Your browser does not support the video tag.