Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Bonfare Market #35 Facility 15 E. Grant Line Rd, Tracy Inspection Dec 13, 2011 <br />Name: Address: <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is a Routine and Monitoring Certification Inspection. The following are Minor -Notice to Comply <br />violations: 303, 310 <br />303. The 91 -octane STP sump sensor was raised approximately 4 inches off the lowest point of the <br />sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall be <br />maintained to be able to detect a leak at the earliest possible opportunity. Immediately relocate this <br />sensor to the lowest point of the sump. Sensor was repositioned on site by technician and violation was <br />corrected on site. <br />310. Liquid was observed in the 91 -octane fill sump and STP sump. If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br />Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br />regulations, and manage it accordingly. Ensure that the sump is maintained free of liquid. Liquid was <br />removed on site by technician and violation was corrected on site. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S C RENT HOURLY RATE. <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 <br />Other: <br />See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />This is a Routine and Monitoring Certification Inspection. The following are Minor -Notice to Comply <br />violations: 303, 310 <br />303. The 91 -octane STP sump sensor was raised approximately 4 inches off the lowest point of the <br />sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall be <br />maintained to be able to detect a leak at the earliest possible opportunity. Immediately relocate this <br />sensor to the lowest point of the sump. Sensor was repositioned on site by technician and violation was <br />corrected on site. <br />310. Liquid was observed in the 91 -octane fill sump and STP sump. If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br />Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br />regulations, and manage it accordingly. Ensure that the sump is maintained free of liquid. Liquid was <br />removed on site by technician and violation was corrected on site. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S C RENT HOURLY RATE. <br />