My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
15
>
2300 - Underground Storage Tank Program
>
PR0231404
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2021 3:00:37 PM
Creation date
6/23/2020 6:47:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231404
PE
2361
FACILITY_ID
FA0002915
FACILITY_NAME
TRACY MARKET INC
STREET_NUMBER
15
Direction
E
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21435004
CURRENT_STATUS
01
SITE_LOCATION
15 E GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\G\GRANT LINE\15\PR0231404\PERMANENT INJUNCTION & FINAL JUDGMENT 1-15-10.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPASER CONTAINMENT DC TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description Diso # 1/2 DisD # 3/4 DisD # 5/6 <br />UDC manufacturer <br />Total Containment <br />Total Containment <br />Total Containment <br />UDC material <br />FRP <br />FRP <br />FRP <br />UDC depth (inches) <br />30" <br />30" <br />30" <br />Height from UDC bottom to highest <br />piping penetration <br />13" <br />13" <br />13" <br />Height from UDC bottom to lowest <br />electrical penetration <br />5" <br />5" <br />5" <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Sensor <br />Sensor <br />Sensor <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from UDC bottom (in.) <br />15 <br />15 <br />15 <br />Wait time for water level to stabilize (hr:min) <br />0:03 <br />0:03 <br />0:03 <br />Test start time <br />10:40 AM <br />10:40 AM <br />10:58 AM <br />Initial Probe Reading <br />3.2894 <br />3.6267 <br />4.4898 <br />Test end time <br />10:55 AM <br />10:55 AM <br />11:13 AM <br />Final Probe Reading <br />3.2892 <br />3.6262 <br />4.4889 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0002 <br />-0.0005 <br />-0.0009 <br />Pass/Fail threshold (±0.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />0 2006 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.