Laserfiche WebLink
Am <br /> San Joaquin County NW <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> 3 Pt ,r 1.111, <br /> ergroul + Storage 3 . ` ctior <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#3138 1153 LINCOLN BLVD, TRACY August 16, 2016 <br /> hum <br /> .9� I$€ at t "� h,- •' VLA . a;. 1 comrii) <br /> fl. <br /> Item# Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the secondary containment test on several <br /> designated operator monthly inspection reports including the June 8, 2016 report. The correct secondary <br /> containment test date for this report is July 25, 2013. During the monthly inspection, the designated operator shall <br /> check that all required testing and maintenance for the UST system have been completed and document the dates <br /> they were done. Ensure that designated operators performing monthly inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The 87 STP sump piping did not have the test boot pulled back and the Schrader valve was pointing up. Any <br /> potential release from the primary containment into the secondary containment in the piping does not flow into a <br /> collection sump. All secondary containment systems shall be sloped so that all releases will flow to a collection sump <br /> located at the low point of the underground piping. <br /> The testing technician rotated the test boot to point the Schraeder valve down. <br /> This is a Class II violation. <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> The 87 tank annular liquid sensor failed to activate an audible and visual alarm when tested to ensure continuous <br /> monitoring of the tank system. All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. The sensor was replaced and retested during the <br /> inspection. A"UST Retrofit Verification with Inspector Already Onsite" form has been completed and will be provided <br /> to the operator and contractor. <br /> This is a minor violation. <br /> 310 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs. <br /> The Bravo box float and chain in the dispenser 1/2 UDC sump failed to stop the flow of product at the dispenser when <br /> tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br /> product at the dispenser when it detects a leak. The service technician cleaned the float cup and verified <br /> functionality. <br /> This is a minor violation. <br /> Page 4 of 5 <br />