My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 12:59:10 PM
Creation date
6/23/2020 6:47:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL*
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3725\PR0231417\ENFORCEMENT\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
505
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd/unitiii.htmi <br /> CONTINUATION FORM Page: 3 of 4 <br /> OFFICIALINSPECTION PORT Date: 01/05/11 <br /> Facility Address: Tracy Shell 3725 North Tracy Blvd, Tracy Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Annual Monitoring System Certification <br /> 3. UST facility form on file with EHD is incomplete. On Facility Form A, the document is missing the BOE <br /> UST Storage Fee Account Number. Any change of information on these forms must be submitted to the <br /> EHD within 30 days of the changes. Immediately complete and submit a copy of the completed facility <br /> form to the EHD by 02/07/11. <br /> 4. Financial responsibility documents have not been submitted to the EHD for both 2010 and 2011 year. <br /> Facility had new owner/ operator around 07/2010. Current financial responsibility documents are <br /> required to be submitted annually. Complete and submit a copy of the financial responsibility <br /> (Certification of Financial Responsibility & Letter from Chief Financial Officer) for 2011 year by 02/07/11. <br /> 5. The monitoring plan on site are not current and not approved by the EHD. The monitoring plan must <br /> be current and approved by the EHD. Section V. the pipe monitoring liquid leak sensor is listed <br /> incorrectly. Comments section X. information is not correct. Complete and submit a copy of the <br /> monitoring plan for approval by the EHD by 02/07/11. An approved copy will be returned for your <br /> records. <br /> 13. The 91 STP sump sensor failed to activate an audible and visual alarm when tested to ensure <br /> continuous monitoring of the tank system. Per technician, sensor resistance reading were high which <br /> did not allow the audible and visual alarm to trigger. <br /> The 87 STP sump sensor failed to provide positive shut down to the turbine when tested in liquid. <br /> Although it produced an audible and visual alarm, the relay contact was stuck & turbine didn't shut off. <br /> This monitoring equipment is programmed to activate an audible and visual alarm and stop the flow <br /> of product at the turbine when it detects a leak. Correct immediately by having a properly licensed, <br /> trained, and certified contractor replace the failed component with a functional component (LG 113-x <br /> listed, if applicable) and obtain a permit within one business day from the EHD. If the failed component <br /> can't be replaced immediately, there is a possibility that the 91 and 87 UST system may be red tagged <br /> to prevent fuel inputs. <br /> 21. Approximately 3 gallons of liquid was observed in the 91 fill sump. If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br /> regulations, and manage it accordingly. Ensure that the 91 fill sump is maintained free of liquid. <br /> Corrected onsite. Technician placed into Hazardous Waste drum. <br /> ALL END STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Insor Rece ed By: TitleOk--fl�4a : <br /> -Gj?/ <br /> EHD 23-02-003 Rev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.