My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
X88 <br /> 0 STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD # <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY F-j I NEW PERMIT ❑ 3 RENEWAL PERMIT ® 5 CHANGE OF INFORMATION F--j 7 PERMANENTLY CLOSE EL ON SITE I <br /> ONE ITEM F--j 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT E] 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED r 4 <br /> ot ocl <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: cp a,. <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MQfDAY/YEAR) Z!:om� D. TANK CAPACITY IN GALLONS: Z2z 2222 <br /> II.TANK CO NTS IF A-1 IS MARKED,OOdPLETE ITEM C. <br /> A. I MOTOR VEHICLE FUEL ❑ 4 OIL g, c. F la REGULAR UNLEADED 3 DIESEL [:] 6 AVIATION GAS <br /> 2 PETROLEUM ❑ 80 EMPTY r-Vl PRODUCT F-1 lb PREMIUM UNLEADED 4 GASAHOL ❑ 7 METHANOL <br /> F❑1 1C MOGRADE UNLEADED 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT 95 UNKNOWN E5 2 WASTE 2 LEADED 99 OTHER(DESCRIBE IN ITEM D.SELOM <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S. <br /> Ill. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ;e9s UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL F-1 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK <br /> ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM F a l00%METHANOL COMPATIBLEWIFFIP <br /> (Pdoo"Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL E] 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ED 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING 4 PHENOLIC LINING <br /> LINING OR F-1 5 GLASS LINING 6 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES— NO— <br /> D.EXTERIOR ❑ i POLYETHYLENE WRAP [:] 2 COATING 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION F1 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> R <br /> SPILL CONTAINMENT INSTALLED(YEAR)— OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> I-SPILL AND OVERFILL,etc. DROP TUBE YES— NO— STRIKER PLATE YES— NO— DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE WF7 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH (�> UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 =COATING A U 8 100%METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION UNKNOWN A U 99 OTHER <br /> D. [:]I MEOMCAL UNE LEAK E]2=TMMfA 3 CONTIIIUM KrERSTRAL 0 4 ffNIC UNE 5 AUTOMATIC IM 99 OTHER <br /> K DETECTION DETECTOR MONTORM DETECTOR [:] SHUTDOWN <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK 2 MANUAL INVENTORY 3 VADOZE 0 4 AUTOMATIC TANK 5 GROUND WATER ANNUAL TANK <br /> F <br /> RECONCILIATION MONITORING GAUGING MONITORING <br /> TESTING <br /> MONITOR <br /> 7 CONTINUOUS INTERSTITIAL 8 SIR 09 WEEKLYGAUGING E]MANUAL ❑10 MONTHLY TANK 95 UNKNOWN 99 OTHER <br /> ING TANKTESTING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST UPED AY R) TY OF 3.WAS TANK FILLED WITH YES F-1 NO <br /> MW REMAINING INERT MATERIAL? <br /> ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,is TRUE AND CORRECT <br /> TANK OWNERS NAME DATE <br /> (PRINTED&SIMATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> C-- <br /> STATE I.Dl 4z!� <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPUWON-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. F0jKC MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT q9 FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THFAIIIIIIIIIiRGROUND STORAGE TANK REGULATIONS <br /> FORMS (6-95) <br />
The URL can be used to link to this page