My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1999-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 1:10:52 PM
Creation date
6/23/2020 6:47:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2011
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1999-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />Results of Third Party Standard Evaluation <br />Point Sensor Liquid Contact Product Detectors <br />This form documents the performance of the cable sensor liquid contact leak detection system described below. <br />The evaluation was conducted by the equipment manufacturer or a consultant to the manufacturer according to the <br />Third Party Procedures developed according to the U.S. EPA's "Standard Test Procedure for Evaluating Leak <br />Detection Methods: Liquid -Phase Out -of -Tank Product Detectors.»1 <br />Tank owners using this leak detection system should keep this form on file to prove compliance with the federal <br />regulations. Tank owners should check with state and local agencies to verify that this form satisfies their <br />requirements. <br />Method Description <br />Name TLS -350/300/300i Series UST Monitoring System <br />Version with Interstitial Liquid Sensor for Fiberglass Tanks (0794390-401,404,407,409L <br />Vendor Veeder-Root Environmental Products <br />125 Powder Forest Drive <br />(street address) <br />Simsbury. CT 06070-2003 (800) 873-3313 <br />(city) (state) (zip) (phone) <br />Detector output type: X Qualitative <br />Detector operating principle: Electrical Conductivity Capacitance Change <br />Interface Probe Product Permeable Product Soluble Thermal Conductivity <br />Pressure Switch Magnetic Switch X Other (Float Switch) <br />Detector sampling frequency: Intermittent X Continuous <br />Evaluation Results <br />The detector described above was tested for its ability to detect test liquids in contact with the <br />point sensor. The following parameters were determined: <br />• Detection Accuracy - The measure of sensor response to the presence of liquids. <br />• Response Time - Amount of time the detector must be exposed to liquid before it responds. <br />• Recovery Time - Amount of time that passes before the detector returns to its baseline reading <br />after the test liquid is removed. <br />• Lower Detection Limit - The smallest liquid concentration that the detector can reliably detect. <br />• Product Activation Height - The height of liquid to cause sensor activation. <br />• Specificity - Indicates the level of response, of the detector, to several different liquids. <br />1 Carnegie Mellon Research Institute. Test Procedures for Third Party Evaluation of Leak Detection Methods: Point <br />Sensor Liquid Contact Leak Detection Systems: Final Report - November 11, 1991. <br />Liquid Contact Product Detector - Results Form Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.